Page Background

7/109

Technical

Section 11

Dimensions

Section 12

7

16453.

16462.

16542.

16453 + 16550.

Sealable cover.

CH/CI counters

Metering and

measurement

Application

The CH counters measure the total operating time of any load. The CI counters

count 230Vac pulses from devices such as utility meters or people counters.

Specific technical data

CH

Electromechanical display

Maximum display:

99999.99 hours

Display accuracy:

0.01%

Without reset

Storage temperature:

-25°C to +85°C

Connection:

Tunnel terminals for 2.5mm

2

cable

Consumption:

0.15VA

Operating temperature:

-10°C to +70°C

Mounting on symmetrical

rail

CI

Supply and metering

voltage:

230Vac, 50/60 Hz

Consumption:

0.15VA

Maximum display:

9 999 999 impulses

Without reset

Metering data

Minimum impulse time: 50ms

Minimum time between 2 impulses: 50ms

Storage temperature:

-25°C to +85°C

Operating temperature:

-10°C to +70°C

Connection:

Tunnel terminals for 2.5mm

2

cable

CH

CI

Load

CH

2 3

Load

CI

2 3

Kwh

Type

Control

voltage

Width

in 18mm

ways

Part

number

CH

230Vac

2

15440

CI

230Vac

2

15443