![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0045.jpg)
43
1 : Supplied with short ferrule
Conform to standard EN 60947-1
Insulation voltage according to EN 60947-1/IEC 60664-1 : 500 V
Impulse (surge) voltage (Uimp) : 8 kV
Degree of pollution : 3 (conductive dust)
Self-extinguishing 960 °C for active part supports
Connection with or without Starfix ferrules
0048 88 + 0048 45 (p. 42)
0048 79
Pack
Cat. Nos.
Modular style blocks
Fixing on rail
4
or on plate using 2 screws
Supplied complete with rear insulated plate and
transparent cover
Bar identification possible using CAB 3 markers
When installing under a front plate a blank can also
be clipped on to the front plate
Additional IP 2X terminals can be fitted
(see table opposite)
Double pole
Equipped with 2 bars
Ipk peak
Number
Ways Capacity
withstand Icw
of
per bar
rigid
flexible
current
modules
(mm
2
)
(mm
2
)
(kA)
(kA)
5
0048 81
40 A
11 1·5 to 4 0·75 to 4 20
3
6
2
6 to 16 4 to 10
10
0048 80
100 A
5 2·5 to 10 1·5 to 10 20
4·5
4
2 10 to 25 6 to 16
5
0048 82
125 A
11 2·5 to 10 1·5 to 10 18
4·5
8
2 10 to 25 6 to 16
2 10 to 35 10 to 25
Four pole
Equipped with 4 bars
Ipk peak
Number
Ways Capacity
withstand Icw
of
per bar
rigid
flexible
current
modules
(mm
2
)
(mm
2
)
(kA)
(kA)
5
0048 85
40 A
11 1·5 to 4 0·75 to 4 20
3
6
2
6 to 16 4 to 10
10
0048 84
100 A
5 2·5 to 10 1·5 to 10 20
4·5
4
2 10 to 25 6 to 16
5
0048 86
125 A
7 2·5 to 10 1·5 to 10 20
4·5
6
2 10 to 25 6 to 16
2 10 to 35 10 to 25
5
0048 88
1
125 A
11 2·5 to 10 1·5 to 10 14·5 4·2
8
4 10 to 35 6 to 25
1
1
0048 79
1
160 A
1 35 to 70 35 to 70 27
8·4
10
8 2·5 to 10 1·5 to 10
4 10 to 25 6 to 16
2 10 to 35 10 to 25
1
n
Dimensions
Double pole 40 - 100 - 125 A
Extend your wiring capability using IP 2X fully shrouded terminals
(see p. 42) on the following :
Four pole 40 - 100 - 125 A
Four pole 160 A
004882-67463c.eps
44
50
L
49
39 23
004888-67464c.eps
88 . 5
86
23
44
50
L
004880-67467q.eps
44
50
96 . 8
91 . 5
23
L
004879-67465c.eps
Distribution
IP 2X
Characteristics
block Cat. Nos.
Terminal
Voltage Rating
0048 80
0048 32
1
400 V
80 A
0048 81
0048 34
1
400 V
40 A
0048 82
0048 35
1
400 V
100 A
0048 84
0048 42
2
400 V
80 A
0048 85
0048 44
2
400 V
40 A
0048 86
0048 44
2
400 V
100 A
0048 88
0048 45
2
400 V
100 A
0048 79
0048 45
2
400 V
100 A
1 :
T
(green cover)
2 : Neutral (blue cover)
Cat. Nos. Length (L)
0048 80
70
0048 81
105
0048 82
140
Cat. Nos. Length (L)
0048 84
70
0048 85
105
0048 86
105
0048 88
140
0048 88 + 0048 45
0048 80 + 0048 32
distribution blocks 40 to 160 A
m
odular style - rail or screw fixing
CAB 3 markers
p. 140-143
Starfix ferrules
p. 148-149
Cat. Nos. Length (L)
0048 79