38

MR

medium rating busbar

feed units

(continued)

, in-line bus switcher and reducers

MR is fully compliant with BS EN 60439-2

Rated currents are at an average ambient temperature of 40° C (over and above the required standard of 35° C)

IP 55 (according to BS EN 60529)

Pack

Cat. Nos.

In-line bus switches

Allows disconnection of part of a

line, while the other is live

Right hand

Weight (kg)

Aluminium

Copper

Rating (A)

Aluminium

Copper

1

504

0

1701

160

23·54

1

504

0

1702

554

0

1702

250

23·56

24·27

1

504

0

1703

554

0

1703

315

23·63

24·50

1

504

0

1704

554

0

1704

400

29·32

25·38

1

504

0

1708

500

29·50

1

504

0

1705

554

0

1705

630

29·73

32·17

1

504

0

1706

554

0

1706

800

29·80

33·90

1

504

0

1707

554

0

1707

1 000

32·11

35·13

Left hand

Weight (kg)

Rating (A)

Aluminium

Copper

1

504

0

1721

160

23·54

1

504

0

1722

554

0

1722

250

23·56

24·27

1

504

0

1723

554

0

1723

315

23·63

24·50

1

504

0

1724

554

0

1724

400

29·32

25·38

1

504

0

1728

500

29·50

1

504

0

1725

554

0

1725

630

29·73

32·17

1

504

0

1726

554

0

1726

800

29·80

33·90

1

504

0

1727

554

0

1727

1 000

32·11

35·13

Pack

Cat. Nos.

Feed units

(continued)

Centre feed units

Feeds a trunking system from an

intermediate position along the

run. Also used to reduce the volt

drop of the line

Weight (kg)

Aluminium

Copper

Rating (A)

Aluminium

Copper

1

504

0

1201

160

17·27

1

504

0

1202

554

0

1202

250

18·13

19·12

1

504

0

1203

554

0

1203

315

18·88

19·40

1

504

0

1204

554

0

1204

400

22·06

20·34

1

504

0

1208

500

22·65

1

504

0

1205

554

0

1205

630

23·24

26·88

1

504

0

1206

554

0

1206

800

24·02

28·67

1

504

0

1207

554

0

1207

1 000

25·70

29·95

Switchboard-transformer

feed units

Feed unit for direct connection of

the busbar to a switchboard or

to the low voltage terminals of a

distribution transformer

Right hand

Weight (kg)

Rating (A)

Aluminium

Copper

1

504

0

1001

160

4·9

1

504

0

1002

554

0

1002

250

5·1

5·7

1

504

0

1003

554

0

1003

315

5·3

6·0

1

504

0

1004

554

0

1004

400

6·4

9·2

1

504

0

1008

500

6·9

1

504

0

1005

554

0

1005

630

7·5

9·3

1

504

0

1006

554

0

1006

800

7·9

11·4

1

504

0

1007

554

0

1007

1 000

8·3

12·9

Left hand

Weight (kg)

Rating (A)

Aluminium

Copper

1

504

0

1011

160

6·0

1

504

0

1012

554

0

1012

250

6·1

6·7

1

504

0

1013

554

0

1013

315

6·2

7·0

1

504

0

1014

554

0

1014

400

11·3

7·8

1

504

0

1018

500

11·4

1

504

0

1015

554

0

1015

630

11·7

14·2

1

504

0

1016

554

0

1016

800

11·8

15·9

1

504

0

1017

554

0

1017

1 000

12·5

17·1

Centre feed unit

In-line bus switch

right hand

In-line bus switch

left hand

Switchboard-transformer

feed units

right hand

Switchboard-transformer

feed units

left hand

Key : How to select the correct configuration and finish

All examples on this page show 4 conductor galvanised lengths

No. of conductors and finish is dictated by the

red

number

0

= 4 conductors. Galvanised

2

= 4 conductors. Painted

1

= 5 conductors. Galvanised

3

= 5 conductors. Painted

Replace

0

with

1

,

2

, or

3

if required

4

5

- - -

0

- - - -

- - -

1

- - - -

- - -

2

- - - -

- - -

3

- - - -

Codes table

Conductors Case

Code

Painted

Painted

Galvanized

Galvanized

MR

MRF

MR-P

MRF-P

-

-

t l

t

i t

Pai ted

l

i

l

i

-P

4

5

- - -

0

- - - -

- - -

1

- - - -

- - -

2

- - - -

- - -

3

- - - -

Codes table

Conductors Case

Code

Painted

Painted

Gal nized

Galvanized

MR

MRF

MR-P

MRF-P

-

-

-

t l

n t r

P i t

i t

l

i

G l

i

-

-

Contact us on +44 (0) 845 600 6266

Rating reducers with disconnector and

fuse holder also available

Dimensions and technical information p. 45-46