Background Image
Table of Contents Table of Contents
Previous Page  21 / 132 Next Page
Information
Show Menu
Previous Page 21 / 132 Next Page
Page Background

21

MS

double sided busbar

low and medium power 63/100/160 A

Pack

Cat. Nos.

63 A trunking lengths

Tap-off outlets are spaced every 1·0 m on both

sides and are fitted with shutters to prevent

accidental contact with live parts

Expansion joints are not required

Standard lengths

Length

Outlet

Weight

(m)

points

(kg)

1

51530101 3

3 + 3 7·890

1

51530116 2

2 + 2 5·260

1

51530115 1·5 1 + 1 3·945

1

51530114 1

1 + 1 2·630

1

51530112 < 1·5

1

51530113 > 1·5

Fire barrier

Lengths are fitted with a fire barrier and are used

to pass through fire-resistant walls

In accordance with DIN 4102-9 and EN 1366-3

Length

Outlet

Weight

(m)

points

(kg)

1

51530131 3

3 + 3 7·990

Thrust unit

Thrust unit to be located at the bottom and is

required for vertical runs or riser applications

exceeding12-15 m

Length

Outlet

Weight

(m)

points

(kg)

1

51530141 3

3 + 3 7·890

Conforms to BS EN 60439-2. Casing manufactured from Senzimir quality galvanised steel suitable for use as a protective earth

IP 40 as standard, increasing to IP 55 with use of appropriate accessories

Pack

Cat. Nos.

100 A trunking lengths

Standard lengths

Length

Outlet

Weight

(m)

points

(kg)

1

51510101

3 3 + 3 7·890

1

51510116

2 2 + 2 5·260

1

51510115 1·5 1 + 1 3·945

1

51510114

1 1 + 1 2·630

1

51510112 < 1·5

1

51510113 > 1·5

Fire barrier

Lengths are fitted with a fire barrier and are used

to pass through fire-resistant walls

In accordance with DIN 4102-9 and EN 1366-3

Length

Outlet

Weight

(m)

points

(kg)

1

51510131 3

3 + 3 7·990

Thrust unit

Thrust unit to be located at the bottom and is

required for vertical runs or riser applications

exceeding 12-15 m

Length

Outlet

Weight

(m)

points

(kg)

1

51510141 3

3 + 3 7·890

160 A trunking lengths

Standard lengths

Length

Outlet

Weight

(m)

points

(kg)

1

51520101 3

3 + 3 9·290

1

51520116 2

2 + 2 6·190

1

51520115 1·5 1 + 1 4·645

1

51520114 1

1 + 1 3·100

1

51520112 < 1·5

1

51520113 > 1·5

Fire barrier

Lengths are fitted with a fire barrier and are used

to pass through fire-resistant walls

In accordance with DIN 4102-9 and EN 1366-3

Length

Outlet

Weight

(m)

points

(kg)

1

51520131 3

3 + 3 10·290

Thrust unit

Thrust unit to be located at the bottom and is

required for vertical runs or riser applications

exceeding 12-15 m

Length

Outlet

Weight

(m)

points

(kg)

1

51520141 3

3 + 3 9·290

L1

N

L2

L3

Tap-off box for 4 modules (see p. 23 ) 51515074 Tap-off box for 8 modules (see p. 23 ) 51515075 End cover (see p. 23) 51501351 Right end feed unit (see p. 22) 51511051 Suspension bracket (see p. 23 ) 51002002 Joint cover (see p. 23) 51500161

Trunking length

51510101

Dimensions and technical information p. 24 Technical data p. 27