BLANKING PLATES

l

Description LIST No

T2 frame MCCB TP blanking kit

17T2B

ANCILLIARIES

l

Description

LIST No

3P Terminal Shields

7T3A3TS

UVR 230V AC or DC

7T3AUV/230

4P Terminal Shields

7T3A4TS

Padlock kit outgoing

7T2ALD

Auxilliary

7T3ACO

Padlock kit incoming

7T3ALD

UVR 110V AC or DC

7T3AUV/110

Shunt Trip 24V/48V

Shunt Trip 230V

AC or DC

7T3AST/48

AC or DC

7T3AST/230

3 POLE GG FRAME MCCBs

I

Rating (A) LIST No Rating (A) LIST No

15

7PBGGN315

50

7PBGGN350

20

7PBGGN320

60

7PBGGN360

25

7PBGGN325

80

7PBGGN380

30

7PBGGN330

100

7PBGGN3100

40

7PBGGN340

125

7PBGGN3125

• Standards: IEC/EN 60947-2

• 25kA Icu at 415VAC

• Fixed thermal and magnetic trips

• Terminal Capacity up to 30A - 16mm

2

above 30A - 50mm

2

BLANKING PLATES

I

Description LIST No

GG Frame MCCB SP blanking kit

17GGB

1 POLE GG FRAME MCCBs

I

Rating (A) LIST No Rating (A) LIST No

15

7PBGGN115

50

7PBGGN150

20

7PBGGN120

60

7PBGGN160

25

7PBGGN125

80

7PBGGN180

30

7PBGGN130

100

7PBGGN1100

40

7PBGGN140

125

7PBGGN1125

• Standards: IEC/EN 60947-2

• 25kA Icu at 240VAC

• Fixed thermal and magnetic trips

• Terminal Capacity up to 30A - 16mm

2

above 30A - 50mm

2

MAIN UNIT MCCBs - 40A TO 250A

I

Description LIST No

250A 36kA Switching Unit

7T2S3250

250A 65kA Switching Unit

7T2H3250

• Standards: IEC/EN 60947-2

• Terminal Capacity 120mm

2

TRIP UNIT OVERLOAD SETTINGS

I

Rated Current

I

n:

100A

7T210/OR3

Overload protection

I

r: 40, 43, 46, 48, 50, 55, 58, 61, 63, 69, 72, 76,

80, 87, 91 and 100A

Rated Current

I

n:

160A

7T216/OR3

Overload protection

I

r: 63, 69, 72, 80, 87, 91,100, 110, 115, 120, 125,

130, 137, 144, 150 and 160A

Rated Current

I

n:

250A

7T225/OR3

Overload protection

I

r: 100, 110, 115, 125, 137, 144,160, 172, 180,

190, 200, 210, 220, 231, 243 and 250A

Restart: T

(0),

T

(t)

Instantaneous short circuit protection:

I

i = 4 x

I

r,

I

i = 8 x

I

r

The rating of these MCCBs is defined by selection of the appropriate

overcurrent release.

THE SWITCHING UNIT MUST BE FITTED WITH AN OVERCURRENT RELEASE

MODULE.

38

ETU DP

I =250A

CATEGORY A

TRMS

RESTART

n

I (A)

i

I

I (A)

r

TEST

I

r

I

i

172

160

144

137

125

115

110

100

180

190

200

210

220

231

243

250

8xl

r

4xl

r

l

r

T

(0)

T

(t)

l

i

TRIP

>110%

110%

80%

30%

RUN

7T2S3250 + OR

17T2B

1 Pole MCCB

3 Pole MCCB

POWERSTAR 250

OUTGO I NG MCCB s