Background Image
Table of Contents Table of Contents
Previous Page  93 / 425 Next Page
Information
Show Menu
Previous Page 93 / 425 Next Page
Page Background

Full range of product

and technical information

place this part number

in a search engine and

download

2CDC110004C0206

1/85 control

ABB Low Voltage Industrial Products 0312

1

Relays and optocouplers

Optocouplers - R600

Optocoupler : 5 to 58 V DC output / 100 mA - 6 mm .236’’ spacing

OB...IC 0100

5 V DC - 12 V DC

24 V DC

48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC

50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz

5 mA

9 mA

4 mA

4 mA

5 mA

7 mA / 16mA 11.5 mA/25 mA

4 V

4 V

15 V

25 V

25 V

60 VAC/70 VDC 60 VAC/70 VDC

10 μs / 500 μs

10 μs / 500 μs

5 ms / 20 ms

5 ms / 15 ms

1000 Hz

1000 Hz

20 Hz

20 Hz

0,9 mA

1 mA

0,9 mA

1,6 mA

1 mA

100 mA

< 50 μA

1 V

1,3 V

UL 94 V0

UL 94 V0

0,2 - 4 mm² / 24 - 12 AWG

0,2 - 2,5 mm² / 24 - 12 AWG

0,22 - 2,5 mm² / 24 - 12 AWG

0,22 - 2,5 mm² / 24 - 12 AWG

2,5 mm² / 12 AWG

2,5 mm² / 12 AWG

9 mm

.354"

9 mm

.354"

3,5 mm

.137"

3,5 mm

.137"

IP20

NEMA1

IP20

NEMA1

0,4 - 0,6 Nm

3.5 - 5.3 Ib.in

0,4 - 0,6 Nm

3.5 - 5.3 Ib.in

Opto. characteristics

INPUT

Input voltage +20% -15% on

DC, +10% -10% on AC

Frequency

Input current AC/DC

Pull-in voltage at Is=100%

Switching time C / O

Operating frequency

Permissible leakage current

OUTPUT

Output voltage

Output current min.

Output current max.

Output leakage current at

Umax.

Residual voltage at I max and

U rated

typical

max.

Frequency on inductive load

Isolation Input / Output

TEMPERATURE

Ambient temperature storage

operating

Other characteristics

Body material

grey

Wire

Solid wire

size

Stranded wire

Rated wire size

Wire stripping length

Recommended screwdriver

Protection

Recommended torque

Approvals

Reference standards

4,5 to 58 VDC

2500 V RMS

-40°C to +80°C

-20°C to +70°C (1)

Screw clamp

Spring clamp

, (pending) ,

, LRS ,

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IRC 1000-4-2, 3, 4, 5, 6.

Characteristics

(1) Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical

rail mounting use temperature is 15°C less decreased.

Description

Type

Order Code

Price

Optocoupler module 100 mA/DC

OBIC 0100-5-12VDC

1SNA645047R0000

18.43

OBIC 0100-24VDC

1SNA645021R2600

16.67

OBIC 0100-48-60VAC/DC

1SNA645049R1200

20.61

OBIC 0100-115-230VAC/DC 1SNA645022R2700

20.14

Accessories see page 1/80

OB...IC 0100 - 5-12 V DC

115-230 V AC/DC

OB...IC 0100

24 V DC

24-48-60 V AC/DC

center of rail

Screw clamp module

DIN 3