1/80 control
ABB Low Voltage Industrial Products 0312
1
RB...111 A - 24 V AC/DC
RB...111 A48-60-115-230 V AC/DC
RB...111 AR
RB...101 AR
center of rail
Screw clamp module
Spring clamp module
Relays and optocouplers
Relay Interfaces - R600 relay modules
24 VAC/DC 48 VAC/DC 60 VAC/DC 115 VAC/DC 230 VAC/DC 24 VAC/DC 24 VAC/DC 24 VAC/DC
50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
0,24 W
0,34 W
0,54 W
0,46 W
0,8 W
0,24 W
0,24 W
0,24 W
10 mA
7 mA
9 mA
4 mA
3,5 mA
10 mA
10 mA
10 mA
4,5 V
8 V
8 V
17 V
27 V
4,5 V
4,5 V
4,5 V
12 V / 250 V AC
10 mA / 6 A
0,6 W / 140 W
10
7
5 ms
5 ms
5 ms
6 ms
7 ms
5 ms
5 ms
5 ms
8 ms
8 ms
8 ms
15 ms
15 ms
8 ms
8 ms
8 ms
1,2 ms
1,2 ms
1,2 ms
UL 94 V0
UL 94 V0
0,2 - 4 mm² / 24 - 12 AWG
0,2 - 2,5 mm² / 24 - 12 AWG
0,22 - 2,5 mm² / 24 - 12 AWG
0,22 - 2,5 mm² / 24 - 12 AWG
2,5 mm² / 12 AWG
2,5 mm² / 12 AWG
9 mm
.354"
9 mm
.354"
3,5 mm
.137"
3,5 mm
.137"
IP20
NEMA1
IP20
NEMA1
0,4 - 0,6 Nm
3.5 - 5.3 Ib.in
0,4 - 0,6 Nm
3.5 - 5.3 Ib.in
DC12
AC12
DC13
AC15
24 V
6 A
6 A
1 A
3 A
110/120 V 0,3 A
6 A
0,2 A
3 A
220/230 V 0,2 A
6 A
0,1 A
3 A
RB 111 A
RB 111 AI RB 111 AR RB 101 AR
Characteristics
Relay characteristics
COIL
Rated voltage +20%, -15%
on DC ; +10%, -10% on AC
Frequency
Power
Rated current
Drop-out voltage at 20°C
Status device
CONTACT
Type
Voltage switching range min./max.
Current switching range min./max.
Load switching range
AC1 min. / max.
DC1 min. / max.
Number of on-load operations
Number of off-load operations
Operating speed
F
O
Bounce
Insulation coil / contact
Resistance to shock coil / contact
Insulation contact / contact
Ambient temperature
storage
operating
Other characteristics
Body material
grey
Wire
Solid wire
size
Stranded wire
Rated wire size
Wire stripping length
Recommended screwdriver
Protection
Recommended torque
Approvals
Reference standards
±10% on AC
+10% -15% on DC
green LED
green LED green LED
1 NO
1 NO + RC 1 NC + RC
0,6 VA / 1500 VA (ohmic load)
10
5
on AC15
4000 V RMS
3800 V RMS 4000 V RMS
4000 V RMS
1000 V RMS
-40°C to +80°C
-20°C to +70°C (1)
Screw clamp
Spring clamp
, (pending) ,
, LRS ,
CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IRC 1000-4-2, 3, 4, 5, 6.
Limited load in CC
Current (Acc)
Voltage (Vcc)
(1) Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use
temperature is 15°C less decreased.
Relay : 1NO or 1NC high level contact 10 mA to 6 A - 6 mm .236» or 12 mm .472» spacing
Description
Type
Order Code
Price
Relay module 1 NO high level with
safety switch 6 mm spacing
RB 111 A1-24VAC/DC
1SNA645063R2000
POA
Relay module 1 NO high level 6 mm spacing
RB 111 A-24VAC/DC
1SNA645014R2700
10.77
RB 111 A-48-60VAC/D
1SNA645014R2700
10.77
RB 111 A-115VAC/DC
1SNA645016R2100
13.02
RB 111 A-230VAC/DC
1SNA645017R2200
13.59
Relay mod. 1 NO high level w/contact
protection 12 mm spacing
RB 111 AR-24VAC/DC
1SNA645018R0300
18.73
Relay mod. 1 NC high level w/contact
protection 12 mm spacing
RB 101 AR-24VAC/DC
1SNA645019R0400
18.73
Accessories
Type
Order Code
Price
End stop
BADH V0
1SNA116900R2700
POA
BADL V0
1SNA399903R0200
POA
BAM2 V0
1SNA399067R0100
POA
Separator end section
SC612
1SNA290474R0200
0.72
Divisible shunt 10 poles
BJ612-10
1SNA290488R0100
1.03
Divisible shunt 70 poles
BJ612-70
1SNA290489R0200
POA
Screw clamp distribution block sp. 12mm
D4/12-3-3
1SNA345031R2000
POA
D4/12-3R-3R
1SNA345531R2200
POA
Test plug DIA. 2mm
FC2
1SNA007865R2600
POA
Marking method
RC65 RC610
see marking
POA
DIN 3
SC612
BADL
BJ...
FC2
D 4/12-3...
BADH