7/17 jokab safety

ABB Low Voltage Industrial Products 0312

7

Focus II is a new version of our previous light beam/light curtain

Focus. Features such as muting and override are standard in

all Focus II light curtains and light beams. For light curtains,

blanking and break functions are also standard. The optical

sensors on Focus II also have variable frequency.

The Focus

II units are light grids/curtains with safety functions intended

for applications where it is of great importance to protect

persons from a dangerous machine, robot or other automated

systems where it is possible to access to a dangerous area.

Focus II creates a protection field with infrared beams. If any

beam is interrupted the safety mechanism is triggered and the

dangerous machine is stopped. Focus II fulfills the requirements

for non-contact safety equipment type 4 (Focus 4 series)

according to the international regulation standard EN 61496-1.

Units are available with safety heights between 150 and 2400

mm. All electronic control and monitoring functions are included

in the light curtain profiles. External connection is made via a M12

connection at the end of the profile. Synchronization between

transmitter and receiver is achieved optically. No electrical

connection between the units is required. Control and monitoring

of the beam transmission is carried out by two micro-processors

which also give information on the status and alignment of the

light curtain via several LEDs.

Muting and Override included in all Focus II

The ”Muting” and ”Override” functions are available on all Focus

II light grids/curtains and is enabled directly when an indication

lamp LMS is connected. Muting implies that one or more

segments or the whole light curtain can be bypassed during in

and out passage of material.

In the Focus II with Muting there is also an Override function

which makes it possible to bypass the light grid/curtain i.e.

activate the outputs if a machine start is necessary even if one

or more light beams are interrupted. This is the case when the

muting function is chosen and the A and B inputs

A light grid/light curtain with many possibilities

Safety light grids, curtains and scanners

Focus II

Application:

Optical protection in an opening or around a risk area