Page Background

7/13 jokab safety

ABB Low Voltage Industrial Products 0312

7

Safety Relays

Selection

RT6

RT7

RT9

JSBRT11

JSBR4

JSBT4

JSBT5T, BT50T, BT51T

JSBT5, BT50, BT51

JSHT1A/B

JSHT2A/B/C

E1T

JSR1T

JSR2A

JSR3T

Input alternatives

(see also technical data on the next page)

Single-channel, 1 NO from +24 V

Category 1, up to PL c

The input must be closed before the

outputs can be activated. A stop signal

is given when the input is opened.

Two-channel, 2 NO from +24 V

Category 3, up to PL d

Boththeinputsmustbeclosedbeforethe

outputs can be activated. A stop signal

is given if one or both of the inputs are

opened.Boththeinputsmustbeopened

and reclosed before the outputs can be

reactivated. A short-circuit between the

inputs is not monitored by the safety

relay.Category4canonlybeachievedifa

safetydevicewithshortcircuitmonitored

outputs is connected.

Two-channel, 1 NO & 1 NC from +24V

Category 4, up to PL e

One input must be closed and one must

be opened before the outputs can be

activated. A stop signal is given if one or

both of the inputs change position or if

the inputs short-circuit. Both inputs must

be put into their initial position before the

outputs can be reactivated.

Two-channel, 1 NO from 0 V &

Category 4, up to PL e

Boththeinputsmustbeclosedbeforethe

outputs can be activated. A stop signal

is given if one or both of the inputs are

opened.Boththeinputsmustbeopened

and reclosed before the outputs can be

reactivated. A Stop signal is given if

thereisashort-circuitbetweentheinputs.

Safety relays

Safety-

timers

Expansion relays

Interlocking switch/Gate/Hatch

Light curtains

Light beams

Safety mats

Contact strips

Two-hand control device

Emergency stop

Hold to run/enabling device

Foot control device

Area supervision

Time resetting

Time bypassing

Inching

Output expansion

Delayed output