7/19 jokab safety

ABB Low Voltage Industrial Products 0312

7

Technical data - general

Electrical

Safety outputs (OSSD)

Two PNP safety outputs, each sourcing 500mA 24vDC. Short circuit protection.

Voltage drop

< 2,3 v

Leakage current

< 1 mA

Capacitive load

< 250 nF for OSSD output

Inductive load

Please contact us

Test pulse data

Test pulse <300us

Test interval, response time x 0,33

Repetition, response time x 0,66

Power supply

Must meet the requirements of EN/IEC60204-1 and EN/IEC61496-1, and must guarantee safe insulation

from the mains voltage in accordance with IEC60742 and be able to cover a drop of supply voltage of at

least 20 ms.

Protection class (IEC 536 or VDE 106)

lll

Power on delay

<2 s

Insulation resistance

> 20 M ohms

Dielectric voltage strength

350 vAC (1 min)

Connections

Cable length Focus ll

Sheilded cables:

Max. 100m, 0,4mm

2

Max. 50m, 0,2mm

2

Cable length Focas ll Mix

Sheilded cables, M12 connector 8-pin these cables are shipped with the sensors. Maximum length is 0,9m.

Conformity

AOPD (ESPE)

Fll-2-xx-yyyy: Type 2 acc. to EN/IEC 61496-1 and EN/IEC 61496-2

Fll-4-xx-yyyy: Type 4 acc. to EN/IEC 61496-1 and EN/IEC 61496-2

Category

Fll-2-xx-yyyy system is suitable for safety control systems up to category 2 acc. EN 954-1

Fll-4-xx-yyyy system is suitable for safety control systems up to category 4 acc. EN 954-1

Safety integrity level

Focus ll system is suitable for up to SIL 3 per IEC 61508

Performance level

Focus ll type 2 systems is suitable for safety control systems up to Performance level c acc.

EN ISO 13849-1. Focus ll type 4 systems is suitable for safety control systems up to Performance level c

acc. EN ISO 13849-1.

Mean time to dangerous failure (MTTF

d

)

450 years

PFH

2,5*10

-09

Proof test interval

Every 20 years

Safety light grids, curtains and scanners

Focus II