Table of Contents Table of Contents
Previous Page  488 / 578 Next Page
Information
Show Menu
Previous Page 488 / 578 Next Page
Page Background

Steel Sports/Large

Floodlighting

Columns

A range dedicated for use with

Altis, Champion or Mundial for

large scale floodlighting

Description

Cat No.

SAP Code Diagram

ref

Columns

QTCH COL 8M MPL ST DOORx1

STEEL COLUMN, FLANGED BASE, 8M, SINGLE DOOR, SUITABLE TO HOUSE 1 SET OF GEAR FOR

CHAMPION FLOODLIGHT

QCS3C8M1D 96227025

1

QTCH COL 8M MPL ST DOORx2

STEEL COLUMN, FLANGED BASE, 8M, DOUBLE DOOR, SUITABLE TO HOUSE 2 SETS OF GEAR FOR

CHAMPION FLOODLIGHT

QCS3C8M2D 96227026

2

QTCH COL 10M MPL ST DOORx1

STEEL COLUMN, FLANGED BASE, 10M, SINGLE DOOR, SUITABLE TO HOUSE 1 SET OF GEAR FOR

CHAMPION FLOODLIGHT

QCS3C10M1D 96227027

3

QTCH COL 10M MPL ST DOORx2

STEEL COLUMN, FLANGED BASE, 10M, DOUBLE DOOR, SUITABLE TO HOUSE 2 SETS OF GEAR FOR

CHAMPION FLOODLIGHT

QCS3C10M2D 96227028

4

QTCH COL 16M MPL ST DOORx1

STEEL COLUMN, FLANGED BASE, 16M, SINGLE DOOR, SUITABLE TO HOUSE 1 SET OF GEAR FOR

CHAMPION FLOODLIGHT

QCS3C16M1D 96227029

5

QTCH COL 16M MPL ST DOORx2

STEEL COLUMN, FLANGED BASE, 16M, DOUBLE DOOR, SUITABLE TO HOUSE 2 SETS OF GEAR FOR

CHAMPION FLOODLIGHT

QCS3C16M2D 96227030

6

QTCH COL 16M MPL ST DOORx1 FIXx3

STEEL COLUMN, FLANGED BASE, 16M, SINGLE DOOR, TO TAKE 3 CHAMPION FLOODLIGHT.

ALSO ORDER BOLT ON GEAR BOX

QCS3C16M1D3 96227031

7

QTCH COL 16M MPL ST DOORx2 FIXx4

STEEL COLUMN, FLANGED BASE, 16M, DOUBLE DOOR, TO TAKE 4 CHAMPION FLOODLIGHT.

ALSO ORDER BOLT ON GEAR BOX

QCS3C16M2D4 96227032

8

Brackets

QTCH BRA x 1

SINGLE BRACKET FOR CHAMPION FLOODLIGHT, USE ONLY WITH QTCH COLUMNS

QTCHB1

96227033

9

QTCH BRA x 2

TWIN IN LINE BRACKET FOR CHAMPION FLOODLIGHT, USE ONLY WITH QTCH COLUMN

QTCHB2

96227034

10

QTCH BRA x 3

TRIPLE DELTA BRACKET FOR CHAMPION FLOODLIGHT, USE ONLY WITH QTCH COLUMN

QTCHB3

96227035

11

QTCH BRA x 4

QUADRUPLE IN LINE 2 UP/2 DOWN BRACKET FOR CHAMPION FLOODLIGHT,

USE ONLY WITH QTCH COLUMN

QTCHB4

96227036

12

Accessories

QTCH GB

BOLT ON GEAR BOX FOR USE WITH 16M QTCH COLUMNS WHERE 3 OR 4 SETS OF PRE-WIRED GEAR

TRAYS ARE TO BE HOUSED

QTCHBG 96227037

13

QTCH FA KIT FOR QTCH COL 8/10M

SET OF GROUND MOUNTING BOLTS FOR USE WITH QTCH COLUMNS IN 8M & 10M HEIGHTS,

COMPRISING 4 NO M24 J BOLTS,NUTS & WASHERS

QTCHBS1

96227038

14

QTCH TEMPLATE FOR QTCH COL 8/10M GROUND TEMPLATE FOR USE WITH QTCH COLUMNS IN 8M & 10M HEIGHTS

QTCHTP1

96227039

15

QTCH FA KIT FOR QTCH COL 16M

SET OF GROUND MOUNTING BOLTS FOR USE WITH QTCH COLUMNS IN 16M HEIGHT ONLY,

COMPRISING 4 NO M27X850MM STUDS, NUTS & WASHERS

QTCHBS2

96227040

16

QTCH TEMPLATE FOR QTCH COL 16M

GROUND TEMPLATE FOR USE WITH QTCH COLUMNS IN 16M HEIGHT ONLY

QTCHTP2

96227041 on request

Notes:

1. For suitability for specific locations please consult your local engineer.

2. The Limiting Rationalised Wind Loading Regions indicate the maximum load condition the flood pole can sustain. The Region Categories shown are defined by the guidance in Annex A of PD6547: 2004

along with the associated Rationalised Wind Load Factors (X Heavy 566 Nm-2; Heavy 466 Nm-2; Medium 429 Nm-2; and Light 396 Nm-2).

3. For the categorisation of masts, the Rationalised Wind Loading Region indicates the maximum design wind speed and limiting site altitude used for checking the design of the masts to Technical Report No. 7,

using the actual values of lantern weight and windage for the particular arrangement.

4. Where columns or masts are required in locations with a Wind Loading Region category higher than the limiting values shown.

Ordering Guide

•Can be used with Altis, Champion

or Mundial fitting and house the

remote control gear

• Offers 8, 10 or 16m solutions

•Flanged base for bolting down to

a foundation

• Dedicated brackets for different

combinations of Altis, Champion

or Mundial floodlights

•Columns are designed to house 2

sets of control gear within the base

•16m version when used with 3 or

4 fittings/gear sets per column

needs an additional bolt on gear

box (SAP 96227037) to house

separately supplied gear

•Bolt on gear box is supplied with

the necessary bolts to mount onto

the 16m column which is pre-

drilled to accept this

•Columns and brackets are steel

(hot dipped galvanised finish)

•Columns are manufactured from

20 sided tapering folded sheet

steel sections

•16m columns are supplied in 2

sections for on site assembly

•8 and 10m columns are supplied

in 1 section

•Brackets are supplied separately

from the column for on site assembly

•8 and 10m have flanged plates of

400 x 400mm and use 4 number

M24 bolt holes at 300 x 300mm

centres

•16m have flange plates of 450 x

450mm and use 4 number M27

bolt holes at 350 x 350mm centres

•Ground fixing bolts are supplied

as an accessory and not with the

column

•Ground templates are available

as an accessory. The templates

are used on site when casting the

concrete foundation to ensure the

correct positioning of the bolts in the

foundation such that they line up

with the column flange plate holes

www.thornlighting.co.uk

488