Specifications
Compatible with LED luminaires with separate DC LED drivers.
For maintained or non-maintained emergency lighting systems.
Conforms to EN 61347-1 and EN 61347-2-7.
Suitable for use in luminaires for high-risk task area lighting.
Voltage change-over threshold according to EN 60598-2-22.
3 hours rated duration.
Internal Li-ion battery for improved lifespan allowing frequent partial discharge without
capacity reduction.
Over-charge, over-current, short-circuit and deep discharge protection for battery.
Green charging status LED.
Features
Output Wattage
Output Current
Output Voltage
Input Voltage
Input Current (max)
Emergency Conversion Time
Emergency Operation Time
Battery
2.3-3.3W
50-130mA
9-58Vdc
220-240Vac
50-60Hz
35mA
1s
>3h
Samsung Li-ion KBAT2600
Battery Capacity
Discharge Current (Max)
Charging Time
Battery Life
Protection
Test Function
Order Code
2600mAh
600-700mA
12h
4 Years
IP20, Class II
Independent Driver
Manual
CEW030LIL58-130N