C-TEC’s FP Range of

conventional fire alarm

control panels is one of

the most robust and

cost-effective available.

Fully compliant with

BS 5839 part 4, the range encompasses no less than ten

different variants, covering 1 to 14 zones.

The size, durability and flexibility of the range makes it ideal for use in

all types of commercial and residential property including small shops,

factories, schools, warehouses, offices and houses in multiple occupation.

Often referred to as ‘the installer’s choice’, easy-to-follow wiring

instructions are printed adjacent to the terminals of all variants and a

lift-off lid guarantees an easy first fix and straightforward maintenance.

The panel’s broad compatibility with virtually all known smoke and heat

detector ranges and its ability to interpret a short circuit in any zone(s)

as a fire or fault condition make it particularly useful for retro-installations.

An optional head removal facility (which utilises C-TEC’s BF378 range

of end-of-line monitoring units) is also available, making the FP fully

compliant with the head removal requirements of BS 5839 part 1.

FP Range Features

Fully compliant with BS 5839 Part 4

Lift-off lid for easy first fix and maintenance

Attractive easy-to-clean polycarbonate front label

Heavy-duty base connections

Robust metal lid and metal back box

Ultra-bright, long-life LED indicators

Built-in 24V power supply and battery charger

Optional head removal facility for compliance

with BS 5839 Part 1

Compatibility with virtually all known

conventional smoke and heat detector ranges

True three wire operation of sounder and

detector circuits (Ov is common) for

considerable cost savings on installation

Separate indicators for open and short circuit

fault, sounder fault and battery/power supply

fault

Non-latching ‘class change’ sounder input,

latching fire and non-latching fault outputs

(available via optional expansion loom)

Fault buzzer mute facility

Space available for the rated capacity

of VRLA batteries

Short circuit = fire facility (pre-1980 BS, no

resistors in call points), selectable on a zone by

zone basis for retro-installations

True battery monitoring circuit

One man walk test and zone isolate facility

(not available on EFP1)

Ancillary connections for repeater panels and

other system add- including fault relay

modules, fire relay modules, sounder delay

relay modules, sounder extender kits, etc

(not available on EFP1)

Easy to follow installation instructions

and log book

Multilingual variants available (subject to

quantities)

of 1-14 ZONE

CONVENTIONAL

FIRE ALARM

CONTROL PANELS