Table of Contents Table of Contents
Previous Page  47 / 210 Next Page
Information
Show Menu
Previous Page 47 / 210 Next Page
Page Background

47

Compact INS-INV250/630

verticalmounting

Functional system

Functional units

Switch-disconnectors

Mounting

Vertical fixed with or without spreaders

600

300

Dd380671.eps

Devices

Direct front handle

Lateral handle

INS250-INV100/250

INS/INV320/400

INS/INV500/630

INS/INV250

Number of devices per row 1

1

1

1

Nb. of vertical modules

8

10

12

8

Mounting plates

03040

03073

03073

03032

Front plates

[Nb. of vertical

modules]

cut-out

03248

[5]

03274

[10]

03274

[10]

-

upstream

03801

[1]

-

03802

[2]

03806

[6]

downstream

03802

[2]

-

-

03802

[2]

Upstream connection

Long terminal shields

(1)

LV429518

LV432594

LV432594

LV429518

Cable-ties

08866 + 08867

(1)

Available for 3P/4P.

Mounting

Vertical fixed with or

without spreaders

300

600

DD380773.eps

Devices

Direct front handle

INS250

INV100/250

INS-INV

320/400

INS-INV

500/630

Number of devices per

row

1

1

1

Nb. of vertical

modules

9

10

12

Mounting plates

03050

03080 03080

Front

plates

[Nb. of

vertical

modules]

cut-out

03251

[9]

03281

[10]

03281

[10]

downstream -

-

03812

[2]

Upstream connection

Long terminal shields

(1)

LV429518 LV432594 LV432594

Cable-ties

08866 + 08868

Downstream distribution Linergy DP 250 A distribution block

Insulated Linergy BW

busbars

Rear Linergy BS

busbars

Linergy BS multi-stage

busbars

Dd381347.eps

Dd381348.eps

DD380777.eps

DD380761.eps

Type of connected devices INS-INV250

INS-INV250 INS-INV

320/630

INS-INV250 INS-INV

320/630

INS-INV250 INS-INV

320/630

Front handle

Lateral handle

3P

4P

3P

4P

Distribution block / busbars

04033

+

03002

> page 92

04034

+

03002

> page 92

04033

+

04037

(2)

+

03003

> page 92

04034

+

04037

(2)

+

03003

> page 92

> page 84

> page 86

> pages 87, 88

Power supply block

-

04060

04074

Connection block

-

04062

must be

made

must be made

must be made

Short/long terminal shields

(1)

-

LV429516 LV432594 LV429518 LV432594 LV429518 LV432594

(2)

Copper spacer.

Downstream

distribution

Distribution

block Linergy

DP 250 A

Insulated Linergy

BW busbars

(3)

Rear Linergy BS

busbars

Linergy BS

multi-stage

busbars

Dd382569.eps

Dd382570.eps

DD380777.eps

Dd382571.eps

Type of

connected

devices

INS250

INV100/250

INS250-

INV

100/250

INS-INV

320/630

INS250-

INV

100/250

INS-INV

320/630

INS250-

INV

100/250

INS-INV

320/630

3P 4P

Distribution

blocks /

Busbars

04033 04034

> page 84

> page 86

> pages 87, 88

+

03011

> page 92

+

03011

>page92

Power supply

block

-

04061

04074

-

-

Connection

block

-

04064 04073

must be made

04065 04075

Short/long

terminal

shields

(1)

-

LV429516 LV432594 LV429518 LV432594 LV429516 LV432592

Barrier

-

included

04198

04197

(3)

Space available at the top of the enclosure after mounting the universal power supply block:

7 modules. Space required by power supply block on insulated Linergy BW busbars

= 5 modules.