1

Presentation

This overview describes all the functions offered by

Masterpact NT and NW devices. The two product

families have identical functions implemented using the

same or different components depending on the case.

Circuit breakers and switch-disconnectors page A-2

Ratings:

b

b

Masterpact NT 630 to 1600 A

v

v

Masterpact NW 800 to 6300 A.

v

v

Circuit breakers type N1, H1, H2, H3, L1.

b

b

Switch-disconnectors type NA, HA, HF.

b

b

3 or 4 poles.

b

b

Fixed or drawout versions.

b

b

Option with neutral on the right.

b

b

Protection derating.

b

b

PB100762-60A

Micrologic control units

page A-8

Ammeter A and Energy E

2.0 basic protection

5.0 selective protection

6.0 selective + earth-fault protection

7.0

(1)

selective + earth-leakage protection

Power meter P

5.0 selective protection

6.0 selective + earth-fault protection

7.0 selective + earth-leakage protection

Harmonic meter H

5.0 selective protection

6.0 selective + earth-fault protection

7.0 selective + earth-leakage protection

External sensor for earth-fault protection.

b

b

Rectangular sensor for earth-leakage protection.

b

b

Setting options (long-time rating plug):

b

b

low setting 0.4 to 0.8 x Ir

v

v

high setting 0.8 to 1 x Ir

v

v

without long-time protection.

v

v

External power-supply module.

b

b

Battery module.

b

b

(1)

Only for ammeter A.

DB101123

DB101124

DB127407

Micrologic 5.0E

40

100

%

%

short time

long time

alarm

menu

Power Meter

page A-20

PB106363A35

PB103360

Masterpact equipped with Micrologic 2 /5 / 6 trip units offer type A (ammeter) or E

(energy) metering functions as well as communication. Using Micrologic sensors

and intelligence, Masterpact provides access to measurements of all the main

electrical parameters on the built-in screen, on a dedicated FDM121 display unit or

via the communication system.

Operating assistance

page A-22

Integration of measurement functions provides operators with operating assistance

functions including alarms tripped by user-selected measurement values, time-

stamped event tables and histories, and maintenance indicators.

Switchboard display unit

page A-23

The main measurements can be read on the built-in screen of Micrologic 5 / 6 trip

units. They can also be displayed on the FDM121 switchboard display unit along

with pop-up windows signalling the main alarms.

Portable data acquisition

page A-28

DB124583

Masterpact and GetnSet.

b

b

Communication

page A-30

COM option in Masterpact.

b

b

Masterpact in a communication network.

b

b

General overview