OPERATING TEMPERATURE

Always check the operating temperature, especially if

the cable tie is to be installed in an application where

extreme temperature may occur. Not all ties are made

with the same material characteristics and some can

become brittle at low temperatures and soften at high

temperatures

Legrand recommends

- Colring polymide 6/6 black cable ties

(operating temperature: -15°C to +120°C)

- Colson polymide 12 black cable ties

(operating temperature: -40°C to +100°C)

ENVIRONMENT

Establish if the cable tie is being used inside or outside.

Exposure to sunlight and UV rays can damage and

break down the material causing the tie to weaken and

fracture. Always choose a UV protected cable tie for

external applications

Legrand recommends

- Colring polyamide 6/6 black or Colson polyamide 12

black UV protected cable ties for external usage

TENSILE STRENGTH

Consider the load that the cable tie will need to deal

with. Tensile strength is the maximum stress that a

material can withstand while being stretched or pulled

before failing or breaking

Legrand recommends

- Colson polyamide 12 black UV protected cable

ties for heavy load applications

HALOGENS

Are halogen free cable ties required?

Halogens are a group of highly reactive elements.

Products containing halogens can produce highly

dangerous gases when burned, and can

therefore be life threatening in the event of a fire

Legrand recommends

- Colring and Colson cable ties, both of which are

halogen free

INTERNAL OR EXTERNAL TEETH

Cable ties with external teeth are particularly useful in

applications where internal teeth could cause damage.

An example of this is for suspended lines, where

damage to insulation needs to be avoided

Legrand recommends

- Colson polyamide 12 black UV protected cable

ties with external teeth

EXTERNAL AGENTS

Ensure that the cable ties are resistant to any

external agents they may be exposed to, such as oils,

greases, petroleum products and chlorinated solvents.

This is particularly important for extreme environments

Legrand recommends

- Colring cable ties for environments where oils,

greases, petroleum products and chlorinated solvents

may be present

- Colson cable ties for environments where oils, greases,

petroleum products, saline mist and diluted acids may

be present

FIRE PROPAGATION

Is there a fire risk? This will affect the type of cable tie

required. We would always recommend fire resistant

cable ties to guarantee the safety of persons and

property in the event of a fire

Legrand recommends

- All Legrand cable ties are flame retardant with a fire

resistance to UL 94