Table of Contents Table of Contents
Previous Page  135 / 210 Next Page
Information
Show Menu
Previous Page 135 / 210 Next Page
Page Background

135

Cat. Nos. 0390 71/72/73/74

A

B'

C

B

A min.

A max.

E

C

H

G

F

D

mm

2

35

70

95

120

150

185

300

AWG

2

00

0000

250

300

350

600

Cable section equivalence table

n

Characteristics of heavy duty plate terminal blocks for

copper bars or cable lugs

n

Separation barriers

Dimensions (mm)

IEC EN 60947-7-1

Fire resistance :

960 °C, IEC EN 60695-2-11

V2 according to UL 94

Insulating material :

polyamide –30 °C to +100 °C

Cat. Nos. 0390 31/32/33/34

Voltage (V) Intensity (A)

Cat. Nos.

IEC

IEC

0390 31/71

1000

125

0390 32/72

1000

192

0390 33/73

1000

269

0390 34/74

1000

415

Dimensions (mm)

Dimensions (mm)

Cat. Nos.

A max. A min.

B

C

D

E

F

G

H

0390 13

227

155

36

82

73

88

176

185

191

0390 10/14/17

296

200

42

83 . 5

74 . 5

89 . 5

212

221

227

0390 11/15/18

337

216

55

107 . 3 98 . 5 113 . 5

257

266

272

B

A

Cat. Nos. A

B Thickness

0394 77

106

82 8

0394 78

188

102 12

Cat. Nos. 0394 77/78

Cat. Nos.

A

B B'

C

0390 31

M 8

56

84

0390 32

M 10 61

84

0390 33

1

M 10 61

84

0390 34

2

M 12 64

86

0390 71

M 8

55 . 3

84

0390 72

M 10

60 . 4

84

0390 73

M 10

60 . 4

84

0390 74

M 12

63 . 5

86

C

A

B

n

Characteristics of heavy duty terminal blocks for copper

and aluminium cables

IK 04

Conform to IEC 60947-7-1, EN 60947-7-1

UL 1059 and 486 E - CSA 22-2

Fire resistant IEC 60695-2-11 : 960 °C (except cover)

V2 according to UL 94

Insulation voltage Ui : 1000 V

Impulse voltage Uimp : 12 kV

Insulating material :

- polyamide body –30 °C to +100 °C

- polypropylene cover –25 °C to +100 °C

Connection table

Currents table

Cable lug - Cable

Cable - Cable

Cable lug - Cable lug

Cat. Nos.

Connection

Width of Screw Connection

Width of Screw Width

(mm

2

)

plate (mm)

Ø

(mm

2

)

plate (mm)

Ø

(mm)

Cable - Cable

0390 10

Rigid or flexible

Rigid or flexible

42

Cu/Al: 35 to 120

Cu: 35 to 70

0390 11

Rigid or flexible

Rigid or flexible

55

Cu/Al: 70 to 300

Cu: 70 to 150

Cable lug - Cable lug

0390 13

Cu/Al: max. 95

28

M 8 Cu/Al: max. 95

28

M 8

36

0390 14

Cu/Al: max. 150

34

M 10 Cu/Al: max. 150

34

M 10

42

0390 15

Cu/Al: max. 300

46

M 12 Cu/Al: max. 300

46

M 12

55

Cable lug - Cable

0390 17

Cu/Al: max. 150

34

M

10

Rigid or flexible

42

Cu: 35 to 95

0390 18

Cu/Al: max. 300

46

M 12

Rigid or flexible

55

Cu: 70 to 150

Cat. Nos.

Current (A)

Short-circuit

Tightening torque

Width

current (kA)

(Nm)

Shunted

I/O

Shunted

I/O

Site

Factory

(mm)

input

currents

input

IEC

IEC CSA UL

Cable - Cable

0390 10

340

250 200 170

14·4

8·4

15

15

42

0390 11

570

400 300 285

36

18

35

35

55

Terminal for cable lug - Terminal for cable lug

0390 13

310

310 250 230

11·4

11·4

15

15

36

0390 14

415

415 340 285

18

18

15

15

42

0390 15

670

670 520 420

36

36

35

35

55

Terminal for cable lug - Cable

0390 17

415

315 210 230

18

11·4

15

15

42

0390 18

670

420 325 285

36

18

35

35

55

Shunts

0394 46

450 max.

6

0394 47

700 max.

10

1 : Previously M 12 + block length 78·5 mm

2 : Previously M 16 + block length 94 mm

Viking 3 heavy duty terminal block

s