1 : Rigid cable capacity - 2 . 5 mm

2

max. only when used with

bridging comb

All V2 polyamide UL94 960 °C to IEC EN 60695-2-11

Compatible with either rigid (0 . 25 mm

2

to 95 mm

2

) or flexible (0 . 25 mm

2

to 70 mm

2

) copper cables

Facility for 2 bridging combs

Compatible with rails

2

depth 15 mm and rails

2

EN 60715 depth 7·5 mm and 15 mm

Range comprises only 2 block heights (2 . 5 mm

2

to 10 mm

2

and 16 mm

2

to 70 mm

2

) ensuring a neat installation

0371 80 + automotive-type fuse

0371 82 + 0371 83 +

0371 85

0371 51

0371 52

0371 84 + 0371 86

0371 87

Pack

Cat. Nos.

Disconnection

1 connection

Disconnection by means of blade type lever, handle

lever or mini lever (with tool)

Open (to be equipped)

Can take a blade-type automotive fuse or a miniature

circuit breaker

Colour

Nominal

cross

section

(mm²)

Capacity

Width

(mm)

Rigid cable

(mm

2

)

Flexible

cable (mm

2

)

20

0371 80 Grey

2 . 5 0 . 25 to 2 . 5 0 . 25 to 2 . 5 6

For fuse cartridge 5 x 20 with handle lever

20

0371 81 Grey

2 . 5 0 . 25 to 2 . 5 0 . 25 to 2 . 5 6

For neutral circuit with blue handle lever

20

0371 82 Grey/blue 2 . 5 0 . 25 to 2 . 5 0 . 25 to 2 . 5 6

For standard circuit with handle lever

20

0371 83 Grey

2 . 5 0 . 25 to 2 . 5 0 . 25 to 2 . 5 6

For standard circuit with mini lever

20

0371 84 Grey

2 . 5 0 . 25 to 2 . 5 0 . 25 to 2 . 5 6

For circuit not broken with handle lever

Circuit not broken by the master isolating device

20

0371 85 Orange

2 . 5 0 . 25 to 2 . 5 0 . 25 to 2 . 5 6

For circuit not broken with mini lever

Circuit not broken by the master isolating device

20

0371 86 Orange

2 . 5 0 . 25 to 2 . 5 0 . 25 to 2 . 5 6

For cartridge 5 x 20 with screwed plug

20

0371 87 Grey

10 0 . 25 to 16 0 . 25 to 10 12

Pack

Cat. Nos.

Blocks for sensors and actuators

For connecting sensors (Cat. No. 0371 51) or

actuators (Cat. No. 0371 52), and their shared

power supply unit when using equipotential

bridging comb

Cat. Nos. 0375 46/47 (wiring diagram p. 127)

3 connections on 3 levels - for sensor

Colour

Nominal

cross section

(mm²)

Capacity

Width

(mm)

Rigid cable

(mm

2

)

Flexible

cable (mm

2

)

50

0371 51

1

Grey

2 . 5

0 . 25 to 4 0 . 25 to 2 . 5 5

3 connections on 3 levels - for actuator

Green/yellow marking for the lower level

Metal base. Screwless fixing on rail

50

0371 52

1

Grey

2 . 5

0 . 25 to 4 0 . 25 to 2 . 5 5

Blown fuse indicators

p. 127

Accessories

p. 126-127

End stops

p. 126

Viking 3 terminal blocks – screw connection

for copper cable (continued)

Accessories

p. 126-127

Technical characteristics

p. 128-129

CAB 3 marking system

p. 140-142

Starfix ferrules and

crimping tools

p. 148-149