LB PLUS

straight lengths – Type A

straight lengths 25-63 A

LB PLUS

straight lengths – Type B

straight lengths 25-63 A

8

Pack

Cat. Nos.

Straight lengths – Type B

Reinforced highly rigid galvanised steel casing

7 m maximum distance between suspension

brackets

Conductors insulated with self-extinguishing

plastic ZH (zero halogen)

Standard tap-off outlets with captive IP 55 plug-

outlet covers

Mechanical separation of the 2 sides of the bar,

(6 and 8 conductors versions)

Protection index IP 55

Impact resistance : IK 07

252 with 2 x 25 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75350102H 25

2

3·0

4

5·45

254 with 4 x 25 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75360102H 25

4

3·0

4

5·55

1

75360103H 25

4

3·0

6

5·60

256 with 6 x 25 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75370101H 25

6

3·0

4 + 4

6·10

258 with 8 x 25 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75380101H 25

8

3·0

4 + 4

6·20

1

75380102H 25

8

3·0

6 + 6

6·35

404 with 4 x 40 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75400102H 40

4

3·0

4

6·00

1

75400103H 40

4

3·0

6

6·10

1

75400111H

1

40

4

1·5

2

3·20

408 with 8 x 40 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75420101H 40

8

3·0

4 + 4

7·10

1

75420102H 40

8

3·0

6 + 6

7·30

1

75420111H

2

40

8

1·5

1 + 1

3·70

634 with 4 x 63 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75440101H 63

4

3·0

4 + 4

7·10

1

75440102H 63

4

3·0

6 + 6

7·30

1

75440111H 63

4

1·5

1 + 1

3·70

Pack

Cat. Nos.

Straight lengths – Type A

Rigid galvanised steel casing

3 m maximum distance between suspension

brackets

Conductors insulated with self-extinguishing

plastic (IEC 60695-2-12 and V0 according to

UL94)

Standard tap-off outlets with captive IP 55 plug-

outlet covers

Protection index IP 55

Impact resistance : IK 07

252 with 2 x 25 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75150101 25

2

3·0

2

3·00

254 with 4 x 25 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75160101 25

4

3·0

2

3·10

1

75160102 25

4

3·0

4

3·20

256 with 6 x 25 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75170101 25

6

3·0

2 + 2

3·65

258 with 8 x 25 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75180101 25

8

3·0

2 + 2

3·75

1

75180102 25

8

3·0

4 + 4

3·85

404 with 4 x 40 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75200101 40

4

3·0

2

3·55

1

75200102 40

4

3·0

4

3·65

1

75200111

1

40

4

1·5

2

2·00

408 with 8 x 40 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75220101 40

8

3·0

2 + 2

4·70

1

75220102 40

8

3·0

4 + 4

4·80

1

75220111

2

40

8

1·5

1 + 1

2·50

634 with 4 x 63 A conductors

Rating Conductors Length

Outlet

Weight

(A)

(m)

points

(kg)

1

75240101 63

4

3·0

2 + 2

4·70

1

75240102 63

4

3·0

4 + 4

4·80

1

75240111 63

4

1·5

1 + 1

2·50

75160102

- - -/- - -

- - -/- - -

2 condutors

25 A

4 condutors

25-40 A

6 condutors

25 A

8 condutors

25-40 A

4 condutors

63 A

2 condutors

25 A

4 condutors

25-40 A

6 condutors

25 A

8 condutors

25-40 A

4 condutors

63 A

- - -/- - -

- - -/- - -

75360102H

1 : For use with both 25 and 40 A systems, and

also 2 and 4 conductor versions

2 : For use with both 25 and 40 A systems, and

also 6 and 8 conductor versions

1 : For use with both 25 and 40 A systems, and

also 2 and 4 conductor versions

2 : For use with both 25 and 40 A systems, and

also 6 and 8 conductor versions

Selection chart p. 6-7 Technical data p. 12 Dimensions and technical information p. 14-15 Selection chart p. 6-7 Technical data p. 13 Dimensions and technical information p. 14-15