LB PLUS
straight lengths – Type A
straight lengths 25-63 A
LB PLUS
straight lengths – Type B
straight lengths 25-63 A
8
Pack
Cat. Nos.
Straight lengths – Type B
Reinforced highly rigid galvanised steel casing
7 m maximum distance between suspension
brackets
Conductors insulated with self-extinguishing
plastic ZH (zero halogen)
Standard tap-off outlets with captive IP 55 plug-
outlet covers
Mechanical separation of the 2 sides of the bar,
(6 and 8 conductors versions)
Protection index IP 55
Impact resistance : IK 07
252 with 2 x 25 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75350102H 25
2
3·0
4
5·45
254 with 4 x 25 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75360102H 25
4
3·0
4
5·55
1
75360103H 25
4
3·0
6
5·60
256 with 6 x 25 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75370101H 25
6
3·0
4 + 4
6·10
258 with 8 x 25 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75380101H 25
8
3·0
4 + 4
6·20
1
75380102H 25
8
3·0
6 + 6
6·35
404 with 4 x 40 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75400102H 40
4
3·0
4
6·00
1
75400103H 40
4
3·0
6
6·10
1
75400111H
1
40
4
1·5
2
3·20
408 with 8 x 40 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75420101H 40
8
3·0
4 + 4
7·10
1
75420102H 40
8
3·0
6 + 6
7·30
1
75420111H
2
40
8
1·5
1 + 1
3·70
634 with 4 x 63 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75440101H 63
4
3·0
4 + 4
7·10
1
75440102H 63
4
3·0
6 + 6
7·30
1
75440111H 63
4
1·5
1 + 1
3·70
Pack
Cat. Nos.
Straight lengths – Type A
Rigid galvanised steel casing
3 m maximum distance between suspension
brackets
Conductors insulated with self-extinguishing
plastic (IEC 60695-2-12 and V0 according to
UL94)
Standard tap-off outlets with captive IP 55 plug-
outlet covers
Protection index IP 55
Impact resistance : IK 07
252 with 2 x 25 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75150101 25
2
3·0
2
3·00
254 with 4 x 25 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75160101 25
4
3·0
2
3·10
1
75160102 25
4
3·0
4
3·20
256 with 6 x 25 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75170101 25
6
3·0
2 + 2
3·65
258 with 8 x 25 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75180101 25
8
3·0
2 + 2
3·75
1
75180102 25
8
3·0
4 + 4
3·85
404 with 4 x 40 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75200101 40
4
3·0
2
3·55
1
75200102 40
4
3·0
4
3·65
1
75200111
1
40
4
1·5
2
2·00
408 with 8 x 40 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75220101 40
8
3·0
2 + 2
4·70
1
75220102 40
8
3·0
4 + 4
4·80
1
75220111
2
40
8
1·5
1 + 1
2·50
634 with 4 x 63 A conductors
Rating Conductors Length
Outlet
Weight
(A)
(m)
points
(kg)
1
75240101 63
4
3·0
2 + 2
4·70
1
75240102 63
4
3·0
4 + 4
4·80
1
75240111 63
4
1·5
1 + 1
2·50
75160102
- - -/- - -
- - -/- - -
2 condutors
25 A
4 condutors
25-40 A
6 condutors
25 A
8 condutors
25-40 A
4 condutors
63 A
2 condutors
25 A
4 condutors
25-40 A
6 condutors
25 A
8 condutors
25-40 A
4 condutors
63 A
- - -/- - -
- - -/- - -
75360102H
1 : For use with both 25 and 40 A systems, and
also 2 and 4 conductor versions
2 : For use with both 25 and 40 A systems, and
also 6 and 8 conductor versions
1 : For use with both 25 and 40 A systems, and
also 2 and 4 conductor versions
2 : For use with both 25 and 40 A systems, and
also 6 and 8 conductor versions
Selection chart p. 6-7 Technical data p. 12 Dimensions and technical information p. 14-15 Selection chart p. 6-7 Technical data p. 13 Dimensions and technical information p. 14-15