15

Building regulations part M is for Access to and use of

buildings. It relates, among other things, to how easy the

controls for the various services and systems for the building

can be operated by those who need to do so.

Key factors that affect the use of switches, socket-outlets

and controls are ease of operation, visibility, height and

freedom from obstruction. It is considered advantageous for

those with limited dexterity for switches on multiple socket

outlets to be separated and for light switches to have larger

rockers. It is also considered reasonable provision to provide

these switches, sockets and controls at a height between

450mm and 1200mm from finished floor level

As far as dwellings are concerned, this applies to a new

building only not to extensions or rewires.

Building regulations

450mm

1200mm

Doorbells

Entry phones

Switches

Sockets

TV Sockets

Telephone Jack Points

Maximum

Minimum

“ Switches & sockets should be mounted

between 450 & 1200mm ”.