Table of Contents Table of Contents
Previous Page  249 / 320 Next Page
Information
Show Menu
Previous Page 249 / 320 Next Page
Page Background

Data is subject to errors and technical modifications.

4.10

Residential

Distribution

Flush Mounted Consumer Units

Design 10

Switch Disconnector Incomer

Split Load

High Integrity

Characteristics:

-

-

Metal switch disconnector incomer consumer units, single row from 10 to 20 outgoing ways.

-

-

All consumer units contain rear cable entry, along with top & bottom knockouts.

-

-

Supplied with a full metal DIN rail, 100A switch disconnector incomer and a full complement of earth and neutral terminals

along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.

-

-

Recommended for use with TT systems when utilising RCBO on outgoing circuits.

-

-

Conforms to BS EN 61439-3 including Annex ZB (16kA rating).

-

-

Adjustable depth in wall 72mm-92mm.

-

-

For dimensions see page

4.16.

Characteristics:

-

-

Metal split load and configurable consumer units, single row from 10 to 16 outgoing ways.

-

-

All consumer units contain rear cable entry, along with top & bottom knockouts.

-

-

Supplied with a full metal DIN rail, 100A switch disconnector incomer and 2 RCCBs and a full complement of earth and

neutral terminals along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.

-

-

Conforms to BS EN 61439-3 including Annex ZB (16kA rating).

-

-

Adjustable depth in wall 72mm-92mm.

-

-

For dimensions see page

4.16.

Characteristics:

-

-

Metal split load and configurable consumer units with ability to protect selected circuits with RCBOs and the remainder of

circuits split across two RCCBs. Single row from 10 to 16 outgoing ways.

-

-

All consumer units contain rear cable entry, along with top & bottom knockouts.

-

-

Supplied with a full metal DIN rail, 100A switch disconnector incomer and 2 RCCBs and a full complement of earth and

neutral terminals along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.

-

-

Conforms to BS EN 61439-3 Including Annex ZB (16kA rating).

-

-

Adjustable depth in wall 72mm-92mm.

-

-

For dimensions see page

4.16.

Description

Size

Cat ref.

10 Way Flush 100A Switch Disconnector Incomer

4

VMLF110

14 Way Flush 100A Switch Disconnector Incomer

5

VMLF114

20 Way Flush 100A Switch Disconnector Incomer

7

VMLF120

Description

Size

Cat ref.

10 Way Flush 100A Switch 2x63A 30mA RCCB

5

VMLF710C

12 Way Flush 100A Switch 2x63A 30mA RCCB

6

VMLF712C

16 Way Flush 100A Switch 2x63A 30mA RCCB

7

VMLF716C

10 Way Flush 100A Switch 2x80A 30mA RCCB

5

VMLF810C

12 Way Flush 100A Switch 2x80A 30mA RCCB

6

VMLF812C

16 Way Flush 100A Switch 2x80A 30mA RCCB

7

VMLF816C

Description

Size

Cat ref.

10 Way Flush High Integrity 100A Switch 2x63A 30mA RCCB

5

VMLF710CU

12 Way Flush High Integrity 100A Switch 2x63A 30mA RCCB

6

VMLF712CU

16 Way Flush High Integrity 100A Switch 2x63A 30mA RCCB

7

VMLF716CU

10 Way Flush High Integrity 100A Switch 2x80A 30mA RCCB

5

VMLF810CU

12 Way Flush High Integrity 100A Switch 2x80A 30mA RCCB

6

VMLF812CU

16 Way Flush High Integrity 100A Switch 2x80A 30mA RCCB

7

VMLF816CU

VMLF110

VMLF710C

VMLF710CU

Sw/D/I

Sw/D/I

RCCB

RCCB

Sw/D/I

RCCB

RCCB