Data is subject to errors and technical modifications.
4.10
Residential
Distribution
Flush Mounted Consumer Units
Design 10
Switch Disconnector Incomer
Split Load
High Integrity
Characteristics:
-
-
Metal switch disconnector incomer consumer units, single row from 10 to 20 outgoing ways.
-
-
All consumer units contain rear cable entry, along with top & bottom knockouts.
-
-
Supplied with a full metal DIN rail, 100A switch disconnector incomer and a full complement of earth and neutral terminals
along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.
-
-
Recommended for use with TT systems when utilising RCBO on outgoing circuits.
-
-
Conforms to BS EN 61439-3 including Annex ZB (16kA rating).
-
-
Adjustable depth in wall 72mm-92mm.
-
-
For dimensions see page
4.16.Characteristics:
-
-
Metal split load and configurable consumer units, single row from 10 to 16 outgoing ways.
-
-
All consumer units contain rear cable entry, along with top & bottom knockouts.
-
-
Supplied with a full metal DIN rail, 100A switch disconnector incomer and 2 RCCBs and a full complement of earth and
neutral terminals along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.
-
-
Conforms to BS EN 61439-3 including Annex ZB (16kA rating).
-
-
Adjustable depth in wall 72mm-92mm.
-
-
For dimensions see page
4.16.Characteristics:
-
-
Metal split load and configurable consumer units with ability to protect selected circuits with RCBOs and the remainder of
circuits split across two RCCBs. Single row from 10 to 16 outgoing ways.
-
-
All consumer units contain rear cable entry, along with top & bottom knockouts.
-
-
Supplied with a full metal DIN rail, 100A switch disconnector incomer and 2 RCCBs and a full complement of earth and
neutral terminals along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.
-
-
Conforms to BS EN 61439-3 Including Annex ZB (16kA rating).
-
-
Adjustable depth in wall 72mm-92mm.
-
-
For dimensions see page
4.16.Description
Size
Cat ref.
10 Way Flush 100A Switch Disconnector Incomer
4
VMLF110
14 Way Flush 100A Switch Disconnector Incomer
5
VMLF114
20 Way Flush 100A Switch Disconnector Incomer
7
VMLF120
Description
Size
Cat ref.
10 Way Flush 100A Switch 2x63A 30mA RCCB
5
VMLF710C
12 Way Flush 100A Switch 2x63A 30mA RCCB
6
VMLF712C
16 Way Flush 100A Switch 2x63A 30mA RCCB
7
VMLF716C
10 Way Flush 100A Switch 2x80A 30mA RCCB
5
VMLF810C
12 Way Flush 100A Switch 2x80A 30mA RCCB
6
VMLF812C
16 Way Flush 100A Switch 2x80A 30mA RCCB
7
VMLF816C
Description
Size
Cat ref.
10 Way Flush High Integrity 100A Switch 2x63A 30mA RCCB
5
VMLF710CU
12 Way Flush High Integrity 100A Switch 2x63A 30mA RCCB
6
VMLF712CU
16 Way Flush High Integrity 100A Switch 2x63A 30mA RCCB
7
VMLF716CU
10 Way Flush High Integrity 100A Switch 2x80A 30mA RCCB
5
VMLF810CU
12 Way Flush High Integrity 100A Switch 2x80A 30mA RCCB
6
VMLF812CU
16 Way Flush High Integrity 100A Switch 2x80A 30mA RCCB
7
VMLF816CU
VMLF110
VMLF710C
VMLF710CU
Sw/D/I
Sw/D/I
RCCB
RCCB
Sw/D/I
RCCB
RCCB