Data is subject to errors and technical modifications.
4.3
Residential
Distribution
Surface Mounted Consumer Units
Design 30
Switch Disconnector Incomer
RCCB Incomer
Time Delayed RCCB Incomer
Characteristics:
-
-
Metal switch disconnector incomer consumer units, single row from 2 to 20 and dual row from 6+6 to 20+20 outgoing ways.
-
-
All consumer units contain rear cable entry. Boards with knockouts also contain top & bottom knockouts - see page
4.15.-
-
Supplied with a full metal DIN rail, 63A or 100A switch disconnector incomer and a full complement of earth and neutral
terminals along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.
-
-
Conforms to BS EN 61439-3 Including Annex ZB (16kA rating).
-
-
For accessories see page
4.11.-
-
For dimensions see page
4.15,refer to board sizes below.
Characteristics:
-
-
Metal RCCB incomer consumer units, single row from 2 to 14 and dual row contains 6+6 outgoing ways.
-
-
All consumer units contain rear cable entry. Boards with knockouts also contain top & bottom knockouts - see page
4.15.-
-
Supplied with a full metal DIN rail, 40A, 63A or 100A 30mA RCCB incomer and a full complement of earth and neutral
terminals along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.
-
-
Conforms to BS EN 61439-3 Including Annex ZB (16kA rating).
-
-
For accessories see page
4.11.-
-
For dimensions see page
4.15,refer to board sizes below.
Characteristics:
-
-
Metal RCCB incomer consumer units, single row 12 outgoing ways.
-
-
All consumer units contain rear cable entry. Boards with knockouts also contain top & bottom knockouts - see page
4.15.-
-
Supplied with a full metal DIN rail 100A 100mA time delayed incomer, 63A 30mA RCCB incomers and a full complement of
earth and neutral terminals along with marking labels, busbar, instructions, rear cable protector plate and meter tail clamp.
-
-
Recommended for use with TT systems (meter tail clamp included).
-
-
Conforms to BS EN 61439-3 Including Annex ZB (16kA rating).
-
-
For accessories see page
4.11.-
-
For dimensions see page
4.15,refer to board sizes below.
Description
Size Cat ref.
Cat ref.
With Knockouts
2 Way 63A Switch Disconnector Incomer
2
VM202
VM202K
6 Way 63A Switch Disconnector Incomer
3
VM206
VM206K
6 Way 100A Switch Disconnector Incomer
3
VM106
VM106K
10 Way 100A Switch Disconnector Incomer
4
VM110
VM110K
14 Way 100A Switch Disconnector Incomer
5
VM114
VM114K
20 Way 100A Switch Disconnector Incomer
7
VM120
VM120K
6+6 Way 100A Switch Disconnector Incomer Dual Row
3 (2)
VM10606
VM10606K
10+10 Way 100A Switch Disconnector Incomer Dual Row
4 (2)
VM11010
VM11010K
14+14 Way 100A Switch Disconnector Incomer Dual Row
5 (2)
VM11414
VM11414K
20+20 Way 100A Switch Disconnector Incomer Dual Row
7 (2)
VM12020
VM12020K
Description
Size Cat ref.
Cat ref.
With Knockouts
2 Way 40A 30mA RCCB Incomer
2
VM402H
VM402HK
6 Way 63A 30mA RCCB Incomer
3
VM406H
VM406HK
6 Way 100A 30mA RCCB Incomer
3
VM306H
VM306HK
10 Way 63A 30mA RCCB Incomer
4
VM410H
VM410HK
10 Way 100A 30mA RCCB Incomer
4
VM310H
VM310HK
14 Way 100A 30mA RCCB Incomer
5
VM314H
VM314HK
6+6 Way 100A 30mA RCCB Incomer Dual Row
3 (2)
VM30606H VM30606HK
Description
Size Cat ref.
Cat ref.
With Knockouts
12 Way Configurable 100A 100mA Time Delay RCCB 63A 30mA RCCB 5
VM712TG
VM712TGK
12 Way 100A 100mA Time Delay RCCB 2 x 63A 30mA RCCB
6
VM766TG
VM766TGK
VM202
VM310H
VM712TG
Sw/D/I
RCCB
RCCB
RCCB
RCCB
RCCB
RCCB
Sw/D/I
Connect
Dual Row
Single Row
Dual Row
Connect
RCCB
Single Row