2.70

Data is subject to errors and technical modifications.

Modular Devices

& Enclosures

Multi-Setting Thermostat - EK187

Technical Data

Technical Specifications

Electrical Characteristics

Voltage Supply

230V +10 -15% 50/60Hz

Consumption

1.5VA

Output

1 Changeover Contact

2A 230V AC1

Functional Characteristics

3 Temperature Ranges

Controllable by External Setting

Comfort: Adjustable from +5 to +30ºC

Reduced: Decrease 2 to 8ºC in

Comparison with Comfort Setting

Frost setting: Adjustable from +5 to

+30ºC

Accuracy ±0.2ºC

Environment

Working Temperature

-10 to +50ºC

Storage Temperature

-20 to +70ºC

Connection Capacity

Flexible

1 to 6mm

2

Rigid

1.5 to 10mm

2

Probe

Maximum Distance 50m

Product Presentation

1. Reference setting: comfort TO

2. Decrease in comparison with reference setting: reduced to TO

3. Frost setting

4. Frost setting override

5. Display of state of output i.e. contact position

6. LED indicating the frost override is on.

7. LED indicating the regulation in comparison with a reduced

setting

Electrical Connection

Main Characteristics

-

Temperature settings controllable by external setting

when associating

a digital time switch, it is possible to regulate the heating in relation with a

program established by the user.

-

2 wires link

between the probe and the unit, enables the easy replacement

of the ambient thermostats of an existing installation.

-

Safety feature for “probe failure”

in case of probe disconnection, the

output will be switched 1 minute in every 4; so that in case of disconnection

during winter, it will protect the installation from frost.

-

Display

of state of the output and of the setting.

Working Principle

EK187

adjusts the temperature under the “all or nothing” principle it

is associated to an ambient probe and thus works in closed loop the

temperature settings are selected by external settings (contacts free of

potential).

EK187

is thus generally associated to a time switch or a digital

time switch in the case of absence of external signal, EK187

regulates the heating in comparison with the reference setting, a switch

enables the override of the dispensation setting.

7

6

5

4

1

2

3

5

10

15 20

25

30

5

10

15 20

25

30

-2

-5

-8

Auto

EK 187

1

9753

2

10864

EK 187

EK 081

EK 082

EK 083

Ph

N

1

2

3

1 3

5

7

9

2

4

6

8 10

EK 187

1

2

3

EK 081

EK 082

EK 083