DeskPod™

technical hotline +44 (0)1268 563720

raised floor systems

Custom designed DeskPods ensure bespoke requirements are matched.

DeskPod Selector Guide

l

Choose a ‘Supply Option’ – other industry standard connectors are available on request

l

Select your preferred wiring configuration

l

Circuit protection options available from MK Sentry range

l

Optional switch available for isolation

l

Choose from a range of standard and non-standard socket outlets

l

Choice of spacers and end caps also available

Supply Options

Wiring Options

OPTION ref.

DESCRIPTION

None

End cap includes 20mm diameter hole for conduit or cable gland

Pre-wired to Tap-off

Module can be supplied pre-wired to supply cord or powertrack tap-off

3

Pole Connector

Wieland GST* or Wago Winsta** standard power

4

Pole Connector

Wieland GST* or Wago Winsta** clean earth system

Dual earth conductors for compliance to High Integrity Earthing

=

,

BS 7671:2008

IEE Wiring Regulations

All end caps include fixing bracket.

*

Wieland GST connectors include retaining clip to minimise risk of accidental disconnection.

**

Wago Winsta and other components available on request.

65

mm

90

mm

90

mm

65

mm

90

mm

90

mm

OPTION ref.

DESCRIPTION

Standard

Single protective conductor

Clean Earth

Additional clean earth protective conductor

High Integrity Earthing

Protective conductor meets requirements for High Integrity Earthing

=

,

BS 7671:2008

IEE Wiring Regulations

Circuit Protection Options

30

mm

110

mm

30

mm

OPTION ref.

DESCRIPTION

Unit Fuse

12.5

A High breaking capacity ceramic fuse to BS EN60127-2

Fuse length: 32mm Fuse diameter: 6.35mm

MCB

16

A*, Type B, Single Pole, 6kA (MK Sentry)

RCD

16

A, 30mA tripping current, Double Pole, 6kA (MK Sentry)

RCBO

10

A*, Type C, 30mA tripping current, Double Pole 6kA

*

Alternative lower circuit protection ratings available on request.

All circuit protection devices are from the MK Sentry range.

RCD’s do not provide overcurrent protection.

Circuit Isolation

OPTION ref.

DESCRIPTION

Double Pole Neon Switch

Double Pole Switch with green neon, switch cover fitted as standard

Custom designed DeskPods

=