Background Image
Table of Contents Table of Contents
Previous Page  21 / 108 Next Page
Information
Show Menu
Previous Page 21 / 108 Next Page
Page Background

21

Cablelink Plus Modular

technical hotline +44 (0)1268 563720

raised floor systems

Pre-Configured Range

To aid fast and simple product selection, storage and installation, a selection of popular pre-configured floorboxes are available to order:

l

2, 3

or 4 module options

l

Supplied with Serviced Power and/or Unserviced Data Plates

l

Choice of standard modules or pre-wired to a unfused tap-off

l

Pre-wired boxes supplied with a choice of 3m or 5m fused tap-off, High Integrity Earthing compliance

as standard

Part no.

Module 1

Module 2

Module 3

Tap-Off

RCD

MK

CRM333 2G Switch Socket Outlet 4G Data Plate LJU6C 4G Data Plate LJU6C NA

CRM333W 2G Switch Socket Outlet 4G Data Plate LJU6C 4G Data Plate LJU6C UT33201 Grey 4mm

2

3

m

RCD

MK

CRM334 2G Switch Socket Outlet 2G Switch Socket Outlet 4G Data Plate LJU6C NA

CRM334W 2G Switch Socket Outlet 2G Switch Socket Outlet 4G Data Plate LJU6C UT33201 Grey 4mm

2

3

m

RCD

MK

CRM336 2G Switch Socket Outlet

Clean Earth

2

G Switch Socket Outlet

Clean Earth

4

G Data Plate LJU6C NA

CRM336W 2G Switch Socket Outlet

Clean Earth

2

G Switch Socket Outlet

Clean Earth

4

G Data Plate LJU6C UT33204 CE Red 4mm

2

3

m

Tap-offs are also available in 5m options, add suffix ‘-5,’ e.g. CRM321W

-5

.

Please note this tap-off is unfused, the track must be derated to a max of 32A

All modules supplied set at 90mm from top of lid to base of module.

Supplied as Grey (GRY) finish, Light Grey (LGY) finish available via MK Design Service, see page 7.

Part no.

Module 1

Module 2

Module 3

Tap-Off

RCD

MK

CRM321 2G Switch Socket Outlet Blank

4

G Data Plate LJU6C NA

CRM321W 2G Switch Socket Outlet Blank

4

G Data Plate LJU6C UT33201 Grey 4mm

2

3

m

All modules supplied set at 90mm from top of lid to base of module.

Supplied as Grey (GRY) finish, Light Grey (LGY) finish available via MK Design Service, see page 7.

Part no.

Module 1

Module 2

Module 3

Module 4

Tap-Off

RCD

MK

CRM431 2G Switch Socket Outlet Blank

Blank

4

G Data Plate LJU6C NA

CRM431W 2G Switch Socket Outlet Blank

Blank

4

G Data Plate LJU6C UT33201 Grey 4mm

2

3

m

RCD

MK

CRM433 2G Switch Socket Outlet Blank

4

G Data Plate LJU6C 4G Data Plate LJU6C NA

CRM433W 2G Switch Socket Outlet Blank

4

G Data Plate LJU6C 4G Data Plate LJU6C UT33201 Grey 4mm

2

3

m

RCD

MK

CRM434 2G Switch Socket Outlet 2G Switch Socket Outlet Blank

4

G Data Plate LJU6C NA

CRM434W 2G Switch Socket Outlet 2G Switch Socket Outlet Blank

4

G Data Plate LJU6C UT33201 Grey 4mm

2

3

m

RCD

MK

CRM436 2G Switch Socket Outlet

Clean Earth

2

G Switch Socket Outlet

Clean Earth

Blank

4

G Data Plate LJU6C NA

CRM436W 2G Switch Socket Outlet

Clean Earth

2

G Switch Socket Outlet

Clean Earth

Blank

4

G Data Plate LJU6C UT33204 CE Red 4mm

2

3

m

RCD

MK

CRM444 2G Switch Socket Outlet 2G Switch Socket Outlet 4G Data Plate LJU6C 4G Data Plate LJU6C NA

CRM444W 2G Switch Socket Outlet 2G Switch Socket Outlet 4G Data Plate LJU6C 4G Data Plate LJU6C UT33201 Grey 4mm

2

3

m

Tap-offs are also available in 5m options, add suffix ‘-5,’ e.g. CRM321W

-5

.

Please note this tap-off is unfused, the track must be derated to a max of 32A

All modules supplied set at 90mm from top of lid to base of module.

Supplied as Grey (GRY) finish, Light Grey (LGY) finish available via MK Design Service, see page 7.

2

Module Configuration – 265x265mm Floorbox

3

Module Configurations – 265x265mm Floorbox

4

Module Configurations – 340x265mm Floorbox

=

In the published 17th Edition of the IEE Wiring Regulations, these requirements are found in Regulation 543.7. (16th Edition = Section 607)