16
raised floor systems
customer services +44 (0)1745 532343
Interact Underfloor Power
Part No.
Description
UK1
Additional slab brackets
UK3
Additional end plates
UK5*
Height adjustable slab bracket – track 17mm, 27mm and 39mm
UK5F*
Height adjustable slab bracket – end feed 17mm, 27mm and 39mm
UKDC
Additional dust cover
*
Fixing brackets should be positioned within 300mm from either end of a track run and
either side of all joints.
Minimum support requirement 3.6m length = 4 brackets, 2.4m length = 3 brackets,
1.2
m length = 2 brackets.
Tap-off Leads
Type
Pin Position
Cable /
Conduit
Current
Rating
Protection 3 metre**
5
metre*
Key
codes
†
2.5
mm
2
4.0
mm
2
2.5
mm
2
4.0
mm
2
STANDARD GREY
N2 L2 PE LSF / LSF
13
A
Fused
UT31301C
UT51301C
16
mm
32
A
Unfused
UT33201
UT53201
16
mm
13
A
Fused
UT31301
UT51301
AUX / PHASE 1
GREEN
PE N1 L1
LSF / LSF
13
A
Fused
UT31302C
UT51302C
16
mm
32
A
Unfused
UT33202
UT53202
16
mm
13
A
Fused
UT31302
UT51302
PHASE 2 GREEN
PE N1
L2
LSF / LSF
13
A
Fused
UT31310C
UT51310C
16
mm
32
A
Unfused
UT33210
UT53210
16
mm
13
A
Fused
UT31310
UT51310
PHASE 3 GREEN
PE N1
L3
LSF / LSF
13
A
Fused
UT31311C
UT51311C
16
mm
32
A
Unfused
UT33211
UT53211
16
mm
13
A
Fused
UT31311
UT51311
ALL PHASE GREEN
PE N1 L1 L2 L3
16
mm
28
A
Unfused
UT33205
UT53205
CE RED
CE N1 L1
PE LSF / LSF
13
A
Fused
UT31304C
UT51304C
16
mm
32
A
Unfused
UT33204
UT53204
16
mm
13
A
Fused
UT31304
UT51304
DUO (RED)
CE N1 L1 N2 L2 PE 20mm
28
A
Unfused
UT33206
UT53206
4
m tap-offs and other alternatives are available on request via MK Design Service, See page 7.
Tap-offs are supplied as single cables inside steel flexible conduit, except those with ‘C’ suffix, which are supplied with 3 or 4 core LSF flex, as appropriate.
*
Unfused tap-offs in excess of 3m, can only be used on powertrack protected with a 32A (or less) circuit protection device.
**
When fully stretched to ensure the conductor lengths do not exceed 3m to comply with BS 7671:2008 17th Edition IEE Wiring Regulations to ensure the conduit remains
flexible this is then shortened by a further 0.1 - 0.2 of slack when wired to a module.
†
Key codes shown are from the perspective of the Power Track socket, the tap-off key code will be a mirror image when viewed from underneath. Add ‘
DE
’
suffix for Dual
Earth High Integrity Earthing
††
,
e.g. UT51301
DE
.
Unfused tap-offs – High Integrity Earthing
††
as standard.
Fused tap-offs – add ‘
607
’
suffix for High Integrity Earthing
††
,
e.g. UT51301
607
Other components
††
In the published 17th Edition of the IEE Wiring Regulations, these requirements are found in Regulation 543.7. (16th Edition = Section 607)