raised floor systems

customer services +44 (0)1745 532343

Interact Underfloor Power

Part No.

Description

UK1

Additional slab brackets

UK3

Additional end plates

UK5*

Height adjustable slab bracket – track 17mm, 27mm and 39mm

UK5F*

Height adjustable slab bracket – end feed 17mm, 27mm and 39mm

UKDC

Additional dust cover

*

Fixing brackets should be positioned within 300mm from either end of a track run and

either side of all joints.

Minimum support requirement 3.6m length = 4 brackets, 2.4m length = 3 brackets,

1.2

m length = 2 brackets.

Tap-off Leads

Type

Pin Position

Cable /

Conduit

Current

Rating

Protection 3 metre**

5

metre*

Key

codes

2.5

mm

2

4.0

mm

2

2.5

mm

2

4.0

mm

2

STANDARD GREY

N2 L2 PE LSF / LSF

13

A

Fused

UT31301C

UT51301C

16

mm

32

A

Unfused

UT33201

UT53201

16

mm

13

A

Fused

UT31301

UT51301

AUX / PHASE 1

GREEN

PE N1 L1

LSF / LSF

13

A

Fused

UT31302C

UT51302C

16

mm

32

A

Unfused

UT33202

UT53202

16

mm

13

A

Fused

UT31302

UT51302

PHASE 2 GREEN

PE N1

L2

LSF / LSF

13

A

Fused

UT31310C

UT51310C

16

mm

32

A

Unfused

UT33210

UT53210

16

mm

13

A

Fused

UT31310

UT51310

PHASE 3 GREEN

PE N1

L3

LSF / LSF

13

A

Fused

UT31311C

UT51311C

16

mm

32

A

Unfused

UT33211

UT53211

16

mm

13

A

Fused

UT31311

UT51311

ALL PHASE GREEN

PE N1 L1 L2 L3

16

mm

28

A

Unfused

UT33205

UT53205

CE RED

CE N1 L1

PE LSF / LSF

13

A

Fused

UT31304C

UT51304C

16

mm

32

A

Unfused

UT33204

UT53204

16

mm

13

A

Fused

UT31304

UT51304

DUO (RED)

CE N1 L1 N2 L2 PE 20mm

28

A

Unfused

UT33206

UT53206

4

m tap-offs and other alternatives are available on request via MK Design Service, See page 7.

Tap-offs are supplied as single cables inside steel flexible conduit, except those with ‘C’ suffix, which are supplied with 3 or 4 core LSF flex, as appropriate.

*

Unfused tap-offs in excess of 3m, can only be used on powertrack protected with a 32A (or less) circuit protection device.

**

When fully stretched to ensure the conductor lengths do not exceed 3m to comply with BS 7671:2008 17th Edition IEE Wiring Regulations to ensure the conduit remains

flexible this is then shortened by a further 0.1 - 0.2 of slack when wired to a module.

Key codes shown are from the perspective of the Power Track socket, the tap-off key code will be a mirror image when viewed from underneath. Add ‘

DE

suffix for Dual

Earth High Integrity Earthing

††

,

e.g. UT51301

DE

.

Unfused tap-offs – High Integrity Earthing

††

as standard.

Fused tap-offs – add ‘

607

suffix for High Integrity Earthing

††

,

e.g. UT51301

607

Other components

††

In the published 17th Edition of the IEE Wiring Regulations, these requirements are found in Regulation 543.7. (16th Edition = Section 607)