3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

3-pole, switchable

7/152

Siemens LV 10 · 2014

* You can order this quantity or a multiple thereof.

7

Selection and ordering data

1)

Fixing screws for mounting on busbars must be ordered separately.

2)

Cu/Al when using suitable cable lugs or terminals.

Rated

operat-

ing cur-

rent

I

e

For fuse

links acc. to

IEC 60269-1

Busbar

center-

to-cen-

ter

spacing

Connection type

(terminal screws/ clamp-

type terminals included in

the scope of supply)

1)

optionally top or bottom

(rotatable!)

For

con-

ductor

material

DT Article No.

Price

per PU

PU

(UNIT,

SET,

M)

PS*/

P. unit

PG Weight

per PU

approx.

A

Size

mm

kg

In-line fuse switch disconnectors, 3-pole switchable

Left:

3NJ4103-3BF01

Right:

3NJ4123-3BF01

160

00 and 000 100 M8 flat connector

Cu/Al

2)

}

3NJ4103-3BF02

1 1 unit

143 1.140

F70 box terminal

Cu

3NJ4103-3BR02

1 1 unit

143 1.135

160

00 and 000 185 M8 flat connector

Cu/Al

2)

3NJ4103-3BF01

1 1 unit

143 2.179

250

1

185 M10 flat connector

Cu/Al

2)

}

3NJ4123-3BF01

1 1 unit

143 5.481

M12 stud terminal

Cu/Al

2)

3NJ4123-3BJ01

1 1 unit

143 5.512

V terminal

Cu/Al

2)

3NJ4123-3BT01

1 1 unit

143 5.908

400

2 and 1 185 M12 flat connector

Cu/Al

2)

}

3NJ4133-3BF01

1 1 unit

143 5.540

M12 stud terminal

Cu/Al

2)

3NJ4133-3BJ01

1 1 unit

143 5.406

V terminal

Cu/Al

2)

3NJ4133-3BT01

1 1 unit

143 5.899

630

3 and 2 185 M12 flat connector

Cu/Al

2)

}

3NJ4143-3BF01

1 1 unit

143 6.165

M12 stud terminal

Cu/Al

2)

3NJ4143-3BJ01

1 1 unit

143 6.321

V terminal

Cu/Al

2)

3NJ4143-3BT01

1 1 unit

143 6.675

In-line fuse switch disconnectors, 3-pole switchable,

with electronic fuse monitoring (EFM)

3NJ41.3-3CF..

160

00 and 000 100 M8 flat connector

Cu/Al

2)

3NJ4103-3CF02

1 1 unit

143 1.540

250

1

185 M10 flat connector

Cu/Al

2)

3NJ4123-3CF01

1 1 unit

143 6.280

400

2 and 1 185 M12 flat connector

Cu/Al

2)

3NJ4133-3CF01

1 1 unit

143 6.350

630

3 and 2 185 M12 flat connector

Cu/Al

2)

3NJ4143-3CF01

1 1 unit

143 7.050

In-line fuse switch disconnectors, 3-pole switchable,

for integratable current transformers

160

00 and 000 100 M8 flat connector

Cu/Al

2)

}

3NJ4103-3BF12

1 1 unit

143 1.110

250

1

185 M10 flat connector

Cu/Al

2)

}

3NJ4123-3BF11

1 1 unit

143 5.192

400

2 and 1 185 M12 flat connector

Cu/Al

2)

}

3NJ4133-3BF11

1 1 unit

143 5.250

630

3 and 2 185 M12 flat connector

Cu/Al

2)

}

3NJ4143-3BF11

1 1 unit

143 6.090

In-line fuse switch disconnectors, 3-pole switchable, for integratable current

transformers, with electronic fuse monitoring (EFM)

160

00 and 000 100 M8 flat connector

Cu/Al

2)

3NJ4103-3CF12

1 1 unit

143 1.500

250

1

185 M10 flat connector

Cu/Al

2)

3NJ4123-3CF11

1 1 unit

143 8.500

400

2 and 1 185 M12 flat connector

Cu/Al

2)

3NJ4133-3CF11

1 1 unit

143 11.500

630

3 and 2 185 M12 flat connector

Cu/Al

2)

3NJ4143-3CF11

1 1 unit

143 7.090

Trans-

former

apparent

power

Rated

apparent

power of

the gTr

fuses

Busbar

center-

to-cen-

ter

spacing

Rated

current

of gTr

fuses

Rated operation-

al current

I

e

with

3NJ4914-8BA00

isolating blade

DT Article No.

Price

per PU

PU

(UNIT,

SET,

M)

PS*/

P. unit

PG Weight

per PU

approx.

kVA kVA

mm A

A

kg

In-line fuse switch disconnectors, 3-pole switchable,

for secondary-side fusing of transformers and incoming block

3NJ4163-3BF01

500

500

185 722 1000

Cu/Al

2)

3NJ4153-3BF01

1 1 unit 143 9.000

630

630

185 909 1250

Cu/Al

2)

3NJ4183-3BF01

1 1 unit 143 12.943

800

2 x 400 185 2 x 577 1600

Cu/Al

2)

3NJ4163-3BF01

1 1 unit 143 15.500

1000 2 x 500 185 2 x 722 2000

Cu/Al

2)

3NJ4173-3BF01

1 1 unit 143 25.520