Accessories and spare parts

2/61

Siemens LV 10.1 · 2011

* You can order this quantity or a multiple thereof.

1)

Except for installing in the left pole for SENTRON VL160X circuit breakers

(3VL1) with RCD module.

2)

In the case of VL400: 3VL9 400-2AJ20 unsuitable for mounting in the right-

hand accessory sub-section.

For auxiliary switch or alarm switch combinations not included in

the kits provided as standard, the mounting adapters specified

can be ordered separately together with the required contact

blocks:

1 HS or 1 AS with NO contact 3SB34 00-0J

1 HS or 1 AS with NC contact 3SB34 00-0K

Note:

A maximum of 6 contact blocks (HS) per circuit breaker

(VL160X, VL160, VL250, VL400; 3VL1 to 3VL4) and a maximum

of 8 contact blocks (HS) per circuit breaker (VL630, VL800,

VL1250, VL1600; 3VL5 to 3VL8) are possible.

Four 3SB34 auxiliary contact blocks and one mounting adapter

(right), suitable for VL630, VL800, VL1250, VL1600 (3VL5 to

3VL8) circuit breakers.

For retrofitting/possible complement see Technical Information

at www.siemens.com/lowvoltage/support.

For circuit

breakers

Maximum combination of

auxiliary switches (HS) and

alarm switches (AS)

DT Order No.

Price

per PU

PU

(UNIT,

SET, M)

PS*/

P. unit

PG Weight

per PU

approx.

Type

kg

3SB adapters and 3SB contact blocks

Mounting adapters for auxiliary and alarm switch combinations

For installation in the N pole of the circuit breaker

VL160X,

Up to 3 HS

1)

A

3VL9 400-2AH00

1 1 unit

113 0.009

VL160,

VL250,

2 HS + 1 AS

1)2)

--

VL400 (3VL1 to 3VL4)

VL630,

VL800,

VL1250,

VL1600 (3VL5 to 3VL8)

Up to 4 HS

A

3VL9 816-2AL00

1 1 unit

113 0.075

2 HS + 2 AS

--

For installation in the left pole of the circuit breaker

VL160X,

Up to 3 HS

1)

A

3VL9 400-2AH00

1 1 unit

113 0.009

VL160,

VL250,

2 HS + 1 AS

1)2)

A

3VL9 400-2AJ10

1 1 unit

113 0.001

VL400 (3VL1 to 3VL4)

VL630,

VL800,

VL1250,

VL1600 (3VL5 to 3VL8)

Up to 4 HS

A

3VL9 816-2AL00

1 1 unit

113 0.075

2 HS + 2 AS

A

3VL9 816-2AN10

1 1 unit

113 0.072

For installation in the right pole of the circuit breaker

VL160X,

Up to 3 HS

1)

A

3VL9 400-2AH00

1 1 unit

113 0.009

VL160,

VL250,

2 HS + 1 AS

1)2)

A

3VL9 400-2AJ20

1 1 unit

113 0.001

VL400 (3VL1 to 3VL4)

2)

VL630,

VL800,

VL1250,

VL1600 (3VL5 to 3VL8)

Up to 4 HS

A

3VL9 816-2AL00

1 1 unit

113 0.075

2 HS + 2 AS

--

For auxiliary/alarm switches

DT Circuit breakers

PU

(UNIT,

SET, M)

PS*/

P. unit

PG Weight

per PU

approx.

Type

VL160X to VL1600 (3VL1 to 3VL8)

Order No.

Price

per PU

kg

Switching blocks for auxiliary and alarm switch combinations

1 NO

B

3SB34 00-0J

1 1 unit

102 0.010

1 NC

B

3SB34 00-0K

1 1 unit

102 0.010