Introduction

2/6

Siemens LV 10.1 · 2011

Benefits

• The compact design of the SENTRON 3VL circuit breakers

coupled with excellent characteristics fulfills the high de-

mands of today's electrical distribution systems.

• These circuit breakers offer a broad product range, improved

technology, space savings and easy operation.

• They are available both in thermal-magnetic (16 A to 630 A)

and in electronic versions (63 A to 1600 A).

Communication

The use of modern communication-capable circuit breakers

opens up completely new possibilities in terms of start-up, pa-

rameterization, diagnostics, maintenance and operation. This al-

lows many different ways of reducing costs and improving pro-

ductivity in industrial plants, buildings and infrastructure projects

to be achieved:

• Fast and reliable parameterization

• Timely information and response can prevent plant

stoppages

• Effective diagnostics management

Measured values are the basis for efficient load management,

for drawing up power demand profiles and for assigning power

to cost centers.

Communication:

• For molded case circuit breakers with communication function

see pages 2/12 to 2/28 and 2/40 to 2/50.

• For accessories, see page 2/98.

• For more information see also chapters "Measuring Devices

and E-Counters" and "Software".

Applications

The different versions of SENTRON 3VL circuit breakers are suit-

able for the following applications:

• Incoming and outgoing circuit breakers in distribution systems

• Switching and protection devices for motors, transformers

and capacitors

• Disconnector units with features for stopping and switching off

in an emergency (main control switches and EMERGENCY-

STOP switches) in conjunction with lockable rotary operating

mechanisms and terminal covers.

The SENTRON 3VL circuit breakers are available in the following

versions:

1. For system protection (in 3- and 4-pole versions)

The overload and short-circuit releases are designed for the

protection of cables, leads and non-motor loads.

2. For motor protection (in 3-pole version)

The overload and short-circuit releases are designed for opti-

mized protection and direct-on-line starting of induction squir-

rel-cage motors. The circuit breakers for motor protection are

susceptible to phase failure and feature an adjustable trip

class. The electronic releases operate with a microprocessor.

3. For starter combinations (in 3-pole version)

These circuit breakers are used both for short-circuit protec-

tion as well as for isolating functions, which may be required

in starter combinations consisting of circuit breakers, overload

relays and motor contactors. These circuit breakers exclu-

sively feature adjustable, instantaneous short-circuit releases.

4. As non-automatic circuit breakers (in 3- and 4-pole versions)

These circuit breakers can be used as feeder circuit breakers,

main control switches or non-automatic circuit breakers with-

out overload protection. They incorporate an integrated short-

circuit self-protection system, eliminating the need for back-

up fuses.

Switching capacity

Standards and specifications

SENTRON 3VL circuit breakers comply with:

IEC 60947-1, EN 60947-1,

IEC 60947-2, EN 60947-2.

Isolating features according to IEC 60947-2, EN 60947-2.

Disconnecting features (main control switches) according to

EN 60204.

The SENTRON 3VL circuit breakers comply in addition with re-

quirements for "disconnector units with features for stopping and

switching off in an emergency" (EMERGENCY-STOP switches) in

conjunction with lockable rotary operating mechanisms (red-yel-

low) and terminal covers.

Please contact Siemens for details of other standards.

The electronic releases of the circuit breakers for motor

protection also fulfill IEC 60947-4-1, EN 60947-2.

VL160X to VL400 circuit breakers can be equipped with a

SENTRON 3VL RCD module. They then comply with

IEC 60947-2 Appendix B.

The SENTRON 3VL RCD module complies with IEC 61000-4-2 to

IEC 61000-4-6, IEC 61000-4-11 and EN 55011, Class B (equiva-

lent to CISPR 11) with regard to electromagnetic compatibility.

Operating conditions

The SENTRON 3VL circuit breakers are designed for operation

in enclosed areas.

Suitable enclosures must be provided for operation in areas with

severe ambient conditions (such as dust, caustic vapors, haz-

ardous gases).

Circuit breakers with standard switching capacity N

(

I

cu

up to 55 kA at 415 V)

Circuit breakers with high switching capacity H

(

I

cu

up to 70 kA at 415 V)

Circuit breakers with very high switching capacity L

(

I

cu

up to 100 kA at 415 V)

These switching capacities are indicated in the corre-

sponding tables by the symbols shown on orange back-

grounds.

N

H

L