Options
2/55
Siemens LV 10.1 · 2011
■
Selection and ordering data
✓
Additional price
When ordering, add
"-Z"
to the complete Order No. and add the
relevant order code(s).
Order No. with
"-Z"
1 2 3 4
5
6
7 8
9 10 11 12 13 14 15 16
3VL .. . . - . . . . .
-
. . . .
-Z
and additional order code(s)
Additional
price
@ @ @
+
.
.
.
+
.
.
.
Code for
further versions
-Z
For fixed-mounted circuit breakers (wired in factory)
Prewired internal accessories
Connecting cables (3 m long)
brought out at the rear
This option "L02" can be selected only in combination
with internal accessories
(page 2/57)
.
For VL160X to VL1600
(3VL1 to 3VL8)
L 0 2
✓
Prewired connecting cables for motorized
operating mechanisms
Connecting cables on the circuit breaker for motor-
ized operating mechanisms (3 m long).
On VL160X to VL400 brought out at the top.
On VL630 to VL1600 brought out on the right.
Motorized operating mechanism must be ordered
separately,
see page 2/66
.
This option "L12" can be selected only in combination
with motorized operating mechanisms
(
see page 2/66
).
For VL160X to VL1600
(3VL1 to 3VL8)
L 1 2
✓
Motorized operating mechanisms
with stored
energy mechanisms
for synchronization tasks (24 V DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition
.
available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)
VL400 (3VL4)
VL630, VL800 (3VL5, 3VL6)
M 2 4
✓
✓
✓
Motorized operating mechanisms
for synchronization tasks (42 ... 48 V AC/DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition
.
available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)
VL400 (3VL4)
VL630, VL800 (3VL5, 3VL6)
M 4 2
✓
✓
✓
Motorized operating mechanisms
for synchronization tasks (60 V AC/DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition
.
available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)
VL400 (3VL4)
VL630, VL800 (3VL5, 3VL6)
M 6 0
✓
✓
✓
Motorized operating mechanisms
for synchronization tasks (110 ... 127 V AC/DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition
.
available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)
VL400 (3VL4)
VL630, VL800 (3VL5, 3VL6)
M 1 1
✓
✓
✓
Motorized operating mechanisms
for synchronization tasks (220 ... 250 V AC/DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition
.
available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)
VL400 (3VL4)
VL630, VL800 (3VL5, 3VL6)
M 2 2
✓
✓
✓