Background Image
Table of Contents Table of Contents
Previous Page  55 / 98 Next Page
Information
Show Menu
Previous Page 55 / 98 Next Page
Page Background

Options

2/55

Siemens LV 10.1 · 2011

Selection and ordering data

Additional price

When ordering, add

"-Z"

to the complete Order No. and add the

relevant order code(s).

Order No. with

"-Z"

1 2 3 4

5

6

7 8

9 10 11 12 13 14 15 16

3VL .. . . - . . . . .

-

. . . .

-Z

and additional order code(s)

Additional

price

@ @ @

+

.

.

.

+

.

.

.

Code for

further versions

-Z

For fixed-mounted circuit breakers (wired in factory)

Prewired internal accessories

Connecting cables (3 m long)

brought out at the rear

This option "L02" can be selected only in combination

with internal accessories

(page 2/57)

.

For VL160X to VL1600

(3VL1 to 3VL8)

L 0 2

Prewired connecting cables for motorized

operating mechanisms

Connecting cables on the circuit breaker for motor-

ized operating mechanisms (3 m long).

On VL160X to VL400 brought out at the top.

On VL630 to VL1600 brought out on the right.

Motorized operating mechanism must be ordered

separately,

see page 2/66

.

This option "L12" can be selected only in combination

with motorized operating mechanisms

(

see page 2/66

).

For VL160X to VL1600

(3VL1 to 3VL8)

L 1 2

Motorized operating mechanisms

with stored

energy mechanisms

for synchronization tasks (24 V DC)

Motorized operating mechanism not prewired; if

prewiring for the motorized operating mechanism is

wanted, please specify "L12" in addition.

If internal accessories are provided, the prewiring

option "L02" for internal accessories is already

included. In this case "L02" must not be specified in

addition

.

available with

VL160X, VL160, VL250

(3VL1, 3VL2, 3VL3)

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M 2 4

Motorized operating mechanisms

for synchronization tasks (42 ... 48 V AC/DC)

Motorized operating mechanism not prewired; if

prewiring for the motorized operating mechanism is

wanted, please specify "L12" in addition.

If internal accessories are provided, the prewiring

option "L02" for internal accessories is already

included. In this case "L02" must not be specified in

addition

.

available with

VL160X, VL160, VL250

(3VL1, 3VL2, 3VL3)

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M 4 2

Motorized operating mechanisms

for synchronization tasks (60 V AC/DC)

Motorized operating mechanism not prewired; if

prewiring for the motorized operating mechanism is

wanted, please specify "L12" in addition.

If internal accessories are provided, the prewiring

option "L02" for internal accessories is already

included. In this case "L02" must not be specified in

addition

.

available with

VL160X, VL160, VL250

(3VL1, 3VL2, 3VL3)

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M 6 0

Motorized operating mechanisms

for synchronization tasks (110 ... 127 V AC/DC)

Motorized operating mechanism not prewired; if

prewiring for the motorized operating mechanism is

wanted, please specify "L12" in addition.

If internal accessories are provided, the prewiring

option "L02" for internal accessories is already

included. In this case "L02" must not be specified in

addition

.

available with

VL160X, VL160, VL250

(3VL1, 3VL2, 3VL3)

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M 1 1

Motorized operating mechanisms

for synchronization tasks (220 ... 250 V AC/DC)

Motorized operating mechanism not prewired; if

prewiring for the motorized operating mechanism is

wanted, please specify "L12" in addition.

If internal accessories are provided, the prewiring

option "L02" for internal accessories is already

included. In this case "L02" must not be specified in

addition

.

available with

VL160X, VL160, VL250

(3VL1, 3VL2, 3VL3)

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M 2 2