Background Image
Table of Contents Table of Contents
Previous Page  34 / 36 Next Page
Information
Show Menu
Previous Page 34 / 36 Next Page
Page Background

IAC Touch Screen Display

FEATURES

• Mounts on IAC base unit or

optional panel mounting

• Touch sensitive graphic LCD

screen

• Menu operation for interrogation

and setting

• Back-lit screen for easy viewing

• Communicate with up to 31 IACs

• Battery backed clock

• Displays up to 256 parameters

Touch Screen for IAC 600 Controller

This optional Touch Screen gives access to up to 31* IAC base units on its own sub-

LAN (including the IAC 600, 400, 420 and 200). The Touch Screen can be mounted

direct on the IAC 600 base unit.

The Touch Screen allows the user to interrogate the IACs. Information on sensor

values and outputs can be displayed and parameters can be altered if required. The

Touch Screen’s battery backed clock is used by the IACs on the sub-LAN as a back-up

to their own internal clocks.

*Dependent on the number of parameters to be displayed.

INSTALLATION DETAILS

Power supply:

Powered from the IAC

unit or separate 24 Volt Vac supply

Power failure reserve:

Non volatile RAM

with built-in Real Time Clock gives 3

year back up of clock and memory under

normal conditions of use.

Power Consumption:

2-5 VA

ACCESSORIES

DDC 2601

Remote Touch Screen

Adaptor Kit

Description

IAC-TS

Touch Screen for IAC 600 Controller

Data Sheet 2.951

IAC DISPLAY

FEATURES

• Fully networkable or stand-

alone controllers

• Selectable control applications

(fan-coil applications)

• Low installation cost

• Simple setup using PDA hand-

held computer or PC via infra-red

or RS 232 link

• Designed to maximise

energy savings

• Optional networking

to an MicroNet system

• Supports S-Link sensors

UniFact® Pro Terminal Unit Controllers

The UNIFACTPRO Terminal Unit Controllers have been designed to meet virtually

any fan-coil heating/cooling applications. The controllers can be used as stand-alone

devices or can be networked to MicroNet systems.

The controller has three main switchable modes: comfort (day), night (off) and

economy.

INSTALLATION DETAILS

Control range:

0 to 40°C

Power supply:

230Vac

Power Consumption:

230 Vac @ 12 VA maximum including outputs

Power failure reserve:

EEPROM preserves configuration data and user settings

Controller type

Inputs/outputs

URC-41N-10X

with on/off fan control and S-link support

2 x DI

1 x RI – temperature

1 x AI – setpoint

4 x DO – triacs

3 x DO – relays

URC-51N-10X

with 3-speed fan control and S-link support

Where X denotes the pre-loaded application

(possible to change on the field)

0 = 4-pipe FCU, 1 = 2-pipe with changeover,

2 = DX cooling and electric heater, 3 = airside control

URC-IR-100

Infra-red/RS 232 Receiver

URC-SET-100

NCP Palm Commissioning Software

Data Sheet 10.130

Networkable Terminal Unit Controllers

Terminal Unit

Controllers

34

Satchwell Product Catalogue – SATCHWELL Sigma – IAC Touch Screen Display