7/7 jokab safety

ABB Low Voltage Industrial Products 0312

7

Vital - safety controller

Control of an entire safety system based on the

dynamic safety circuit

Vital is based on a single channel safety

concept where multiple safety sensors can

be connected in series and monitored with

a single safety controller. A dynamic signal is

sent from Vital through all connected sensors,

and then returned to Vital which then evaluates

the received signal. As each safety sensor

inverts the signal, it is possible to detect short

circuits or faults in any of the sensors. Vital

2 and Vital 3 are designed for use with ABB

Jokab Eden sensors, Tina components and

Spot light grids or similar products. Vital 2

and 3 are both safety controllers with two

safe input functions and two output groups,

the only difference between the two models

being in the input configuration.

TÜV Nord – Vital 1

TÜV Rheinland – Vital 2 and 3

Technical data - general data for Vital 1

Level of safety

EN ISO 13849-1

EN 62061

IEC/EN 61508-1…7

EN 954-1

PL e, category 4

SIL 3

SIL 3

Category 4

PFHd

1,01×10-8

Power supply

Vital, A1-A2

From Vital to sensors/units, B1-B2

24 VDC ±15%

24 VDC

Dynamic safety circuit

T 1

R 1

Output signal

Input signal

Reset input X1

Supply for reset input

Reset current

Minimum contact closure time for reset

+24VDC

30 mA max. (inrush current 300 mA

during contact closure)

80 ms

Connection of S1

Even numbers of sensors (Eden + Spot T/R + Tina) require a connection

between B1 and S1. S1 is not connected for odd numbers of sensors. Odd

number, no connection between B1 and S1.

Number of sensors

Max. number of Eden/Tina to Vital 1

Total max. cable length to Eden/Tina

Max. number of Spot T/R to Vital

Total max. cable length to Spot T/R

30

1000 m

6 pairs

600 m

Relay outputs

NO

Max switching capacity, resistive load

Minimum load

Contact material

Mechanical life

External fuse (EN 60947-5-1)

2

6A/250 VAC/1500 VA/150W

10 mA/10V

AgCdO

>10

7

operations

6.3A or 4A slow

Selection

Product Hierarchy 4700002

Type

Part No

Order Code

Price

Vital 2

20-070-43

2TLA020070R4300

288.45

Vital 3

20-070-44

2TLA020070R4400

POA