3VT1 Molded Case Circuit Breakers up to 160 A

Accessories and Components

Manual operating mechanisms

2/25

Siemens LV 36 · 2008

2

Design

Rotary operating mechanisms

The manual operating mechanism permits the actuating of the

circuit breakers/switch disconnectors by turning the knob, e.g.

in order to switch machines on and off. The modular concept of

the operating mechanism allows for simple mounting on the cir-

cuit breaker (even as an add-on). Mounting can be done after

having removed the accessory compartment cover. An affixed

drive may be sealed. The drive and its accessories are ordered

separately according to your choice

(see page 2/7)

.

The manual operating mechanism permits actuating the circuit

breaker:

a) from the front panel (Fig. 1)

3VT9 100-3HA/HB/HC/HD.. rotary operating unit

+ 3VT9 100-3HE/HF.. knob

b) through the control cabinet door (Fig.2)

3VT9 100-3HA/HB/HC/HD.. rotary operating unit

+ 3VT9 100-3HJ.. extension shaft ..

+ 3VT9 100-3HG/HH.. coupling driver

+ 3VT9 100-3HE/HF.. knob

c) through the side wall of the control cabinet (Fig.3)

in left- or right-side designs of manual operating mechanisms for

lateral operation

3VT9 100-3HD10 (right) or 3VT9 100-3HC10 (left)

+ 3VT9 100-3HJ.. extension shaft

+ 3VT9 100-3HG/HH.. coupling driver

+ 3VT9 100-3HE/HF.. knob.

• The manual operating mechanism is mounted directly on the

circuit breaker or switch disconnector.

• The coupling driver is fixed to the control cabinet door and

provides for degree of protection IP40 or IP66.

• The knob is mounted onto the manual operating mechanism

or onto the coupling driver.

• The extension shaft is supplied in two versions, standard

(length 350 mm - can be shortened) and telescopic (adjust-

able length 199 ... 352 mm). It is fitted onto the manual oper-

ating unit.

Enhanced safety for operator

• The manual operating unit and knob are also supplied with the

option to lock the circuit breaker into the “switched off manu-

ally” position. The manual operating unit and lever can be

locked with up to three padlocks with a shaft diameter up to

3 ... 4 mm.

• Every coupling driver prevents the control cabinet door from

opening when the circuit breaker is switched on or in a state

of being switched off by releases. By means of this device, it

is possible to switch off this locking and to open the door.

Locking of the control cabinet door is also possible in the

„switched off manually“state of the circuit breaker. It is neces-

sary to activate the locking by means of the knob on the cou-

pling drive and to lock the hand drive arm.

• Two circuit breakers with manual operating mechanism can

also be provided with reciprocal mechanical interlocking or

mechanical parallel switching

(see page 2/26)

.

Features

Order No.

Description

Color

Locking while the

circuit breaker is

in switched off state

Degree of

Protection

Switchgear door locking in

circuit breaker state

Length

mm

switched on switched off

manually

and locked

3VT9 100-3HA10

Rotary operating mechanism gray

no

--

--

--

--

3VT9 100-3HA20

gray

yes

--

--

--

--

3VT9 100-3HB20

yellow yes

--

--

--

--

3VT9 100-3HC10

Rotary operating mechanism

- lateral, left

grey

no

--

-

--

--

3VT9 100-3HD10

Rotary operating mechanism

- lateral, right

grey

no

--

-

--

--

3VT9 100-3HE10

Knob

black no

--

--

--

--

3VT9 100-3HE20

black yes

--

--

--

--

3VT9 100-3HF20

red

yes

--

--

--

--

3VT9 100-3HG10

Coupling driver

black --

IP40

yes

yes

--

3VT9 100-3HH10

black --

IP40

yes

yes

--

3VT9 100-3HG20

yellow --

IP66

yes

yes

--

3VT9 100-3HH20

yellow --

IP66

yes

yes

--

3VT9 100-3HJ10

Extension shaft

--

--

--

--

--

350 (can be shorted)

3VT9 100-3HJ20

--

--

--

--

--

199 ... 352 telescopic