A-8

Functions and

characteristics

Introduction

Compact NSX trip units

With Micrologic electronic trip units,

Compact NSX stands out from the crowd.

Thanks to the new generation of sensors

and its processing capability, protection is

enhanced even further. It also provides

measurements and operating information.

Thermal-magnetic or electronic trip unit?

Thermal-magnetic trip units

protect against overcurrents and short-circuits using

WULHG DQG WUXH WHFKQLTXHV %XW WRGD\ LQVWDOODWLRQ RSWLPLVDWLRQ DQG HQHUJ\ HI¿FLHQF\

have become decisive factors and electronic trip units offering more advanced

protection functions combined with measurements are better suited to these needs.

Micrologic electronic trip units

FRPELQH UHÀH[ WULSSLQJ DQG LQWHOOLJHQW RSHUDWLRQ

Thanks to digital electronics, trip units have become faster as well as more accurate

and reliable. Wide setting ranges make installation upgrades easier. Designed with

processing capabilities, Micrologic trip units can provide measurement information

and device operating assistance. With this information, users can avoid or deal more

effectively with disturbances and can play a more active role in system operation.

They can manage the installation, anticipate on events and plan any necessary

servicing.

Accurate measurements for complete protection

Compact NSX devices take advantage of the vast experience acquired since the

launch of Masterpact NW circuit breakers equipped with Micrologic trip units.

From 40 amperes on up to the short-circuit currents, they offer excellent

measurement accuracy. This is made possible by a new generation of current

transformers combining "iron-core" sensors for self-powered electronics and "air-

core" sensors (Rogowski toroids) for measurements.

The protection functions are managed by an ASIC component that is independent of

the measurement functions. This independence ensures immunity to conducted and

radiated disturbances and a high level of reliability.

Numerous security functions

Torque-limiting screws

The screws secure the trip unit to the circuit breaker. When the correct tightening

torque is reached, the screw heads break off. Optimum tightening avoids any risk of

temperature rise. A torque wrench is no longer required.

Easy and sure changing of trip units

All trip units are interchangeable, without wiring. Amechanical mismatch-protection

system makes it impossible to mount a trip unit on a circuit breaker with a lower

rating.

"Ready" LED for a continuous self-test

The LED on the front of the electronic trip units indicates the result of the self-test

runs continuously on the measurement system and the tripping release. As long as

WKH JUHHQ /(' LV ÀDVKLQJ WKH OLQNV EHWZHHQ WKH &7V WKH SURFHVVLQJ HOHFWURQLFV DQG

the Mitop release are operational. The circuit breaker is ready to protect. No need for

a test kit. Aminimum current of 15 to 50 A, depending on the device, is required for

this indication function.

A patented dual adjustment system for protection functions.

Available on Micrologic 5 / 6, the system consists of:

D ¿UVW DGMXVWPHQW XQGHU GH HQHUJLVHG FRQGLWLRQV DQG XVLQJ D GLDO VHWV WKH

b

maximum value

D VHFRQG DGMXVWPHQW PDGH YLD WKH NH\SDG RU UHPRWHO\ ¿QH WXQHV WKH VHWWLQJ

b

7KH VHFRQG VHWWLQJ PD\ QRW H[FHHG WKH ¿UVW ,W FDQ EH UHDG GLUHFWO\ RQ WKH 0LFURORJLF

screen, to within one ampere and a fraction of a second.

Coordinated tripping systems

Compact NSX detects faults even faster and its tripping time is reduced. It protects

the installation better and limits contact wear.

DB115565

100

A

E.g. NS

X

100F

1000

A

1500

A

2

400

A

3

6

000

A

I

c

u

Refle

x

threshold

Ii

Isd

Ir

Currents

L

Ti

m

e del

a

y

Prote

c

tion

fun

c

tion

S or S

0

I

1 -

2

00 s

10 - 50

m

s

< 5

m

s

z

2

0 - 500

m

s

z

O

v

erlo

a

d:

S

lo

w

trip inversely

proportion

a

l to

the current level

Inst

a

nt

a

neous:

Ultr

a

-

fa

st detection

w

ith

m

icro del

a

y

f

or discri

m

in

a

tion

Refle

x

:

Ener

g

y-b

a

sed ultr

a

-

fa

st

detection

w

ith

ma

jor current

li

m

itin

g

(1)

Short ti

m

e:

I

m

ped

a

nt short-circuit,

inst

a

nt

a

neous trip

w

ith

a

djust

a

ble

S

or

f

ixed

S

0

ti

m

e del

a

y

(1)

This tripping system is completely independent of the trip unit.

Because it directly actuates the mechanism, it precedes the trip unit by a few milliseconds.

559E1100.indd

version: 1.0