Brushed stainless steel front plates : brushed stainless steel with clear epoxy satin lacquer coating

Polished stainless steel front plates : electroplated stainless steel plate with trivalent chrome for mirror finish

White interiors and rockers

Terminal screws captive and backed off ready for cabling

177

Synergy

®

traditional

socket outlets

Unswitched socket outlets

13 A - 250 V

±

Conform to BS 1363 - Part 2 : 1995

2 earth terminals

Flush mounting back box : min. 25 mm deep

Nominal plate dimensions :

1 gang - 86 x 86 mm

Brushed

Polished

2 gang - 86 x 146 mm

1

7330 65 7332 65

1 gang – unswitched

1

7330 75 7332 75

2 gang – unswitched

Pack

Cat. Nos.

Double pole socket outlets

13 A - 250 V

±

Conform to BS 1363 - Part 2 : 1995

2 earth terminals

Flush mounting back box : min. 25 mm deep

Nominal plate dimensions :

1 gang - 86 x 86 mm

Brushed

Polished

2 gang - 86 x 146 mm

1

7330 60

7332 60

1 gang – switched

1

7330 61

7332 61

1 gang – switched +

red LED power indicator

1

7330 70

7332 70

2 gang – switched

1

7330 71

7332 71

2 gang – switched +

red LED power indicator

1

7330 74

7332 74

2 gang – switched outboard

for standard and clean earth

applications

7332 61

7332 74

7330 71

7330 70

Socket outlets 15 A - 250 V

±

Conform to BS 546 : 1950

Flush mounting back box : min. 35 mm deep

Brushed

Polished

Nominal plate dimensions : 86 x 86 mm

1

7330 88

7332 88

1 gang – unswitched

1

7330 89 7332 89

1 gang – switched

Pack

Cat. Nos.

Key switched socket 13 A - 250 V

±

Conform to BS 1363 - part 2 : 1995

Flush mounting back box : min. 35 mm deep

Brushed

Polished

Nominal plate dimensions : 86 x 146 mm

1

8200 71

8200 72

2 gang single socket with

DP key switch

Socket outlets 2 A - 250 V

±

Conform to BS 546 : 1950

Flush mounting back box : min. 25 mm deep

Brushed

Polished

Nominal plate dimensions : 86 x 86 mm

1

7330 59 7332 59

1 gang – unswitched

7332 59

7330 97

7330 89

Stainless steel

Stainless steel

RCD sockets 13 A - 250 V

±

Conform to BS 7288 : 1990 and

BS 1363 - Part 2 : 1995

Conventional earth pin release shutter

Maximum operating current 16 A

Incorporate a “test and reset” button

Flush mounting back box : min. 25 mm deep

Nominal plate dimensions : 86 x 146 mm

Active (electronically latched)

- trips in the event of a power failure

- suitable in applications where automatic

restoration of supply would be hazardous,

e.g. machinery, power tools

1

7330 97

7332 97

RCD unit 2 gang DP

30 mA active

Passive (mechanically latched)

- does not trip in the event of a power failure

- suitable in applications where automatic

restoration of supply is required, e.g. fridge,

freezer, unmanned areas

1

7330 98

7332 98

RCD unit 2 gang DP

30 mA passive

Stainless steel

Stainless steel

Stainless steel

Stainless steel

Brushed Polished

Flush and surface mounting back boxes p. 187

Red LED power indicator