Page Background

Corridor/Stairwell

Classroom/Conference Room

Private Office

Solution:

klik LCM, 4 channel, with daylight dimming & scene setting

& override switch.

2x occupancy sensors set to absence

2x 2 way retractive wall switches - next to door, next to

screen.

Functional Needs:

Office permenantly occupied 9am to 5pm, lights only come on if

switched by wall switch, switch off automatically after time out.

Corridor must stay lit when any ground floor office is occuped.

Solution:

Klik LCM linked to other offices & corridor/stair well, with retractive

on/off switch and 1 x occupancy sensor set to absence.

Functional Needs:

Occasionally occupied but lighting needs to be on from 9-5pm and

then some lights timed off and some dimmed.

Solution:

LCM with two profiles & daylight dimming at front or standard klik

(digital sensor)

Functional Needs:

Wall switch to switch on/off (x2) or switch on with wall switch

/ off automatically with ability to dim up & down all lights when

occupied.

Dim front row (next to screen)

Dim lights next to windows when sufficient daylight.

From application