Table of Contents Table of Contents
Previous Page  32 / 320 Next Page
Information
Show Menu
Previous Page 32 / 320 Next Page
Page Background

Data is subject to errors and technical modifications.

1.17

Panelboards 630A/800A Rated

630A/800A Incoming 125A/250A Outgoing

Invicta 3 Panelboards (630A/800A Incoming 125A Outgoing)

Invicta 3 Panelboards (630A/800A Incoming 125A/250A Outgoing)

Incomer Kits for 630A/800A Panelboards

Description

Cat ref.

Plain Door

Cat ref.

Glazed door

8 Triple Pole Ways 630A Panelboard

JF608B

JF608BG

12 Triple Pole Ways 630A/800A Panelboard

JF812B

JF812BG

18 Triple Pole Ways 630A/800A Panelboard

JF818B

JF818BG

Description

Cat ref.

Plain Door

Cat ref.

Glazed door

6 Triple Pole Ways Panelboard (2 x 250A

+ 4 x 125A

)

JF60204B

1

JF60204BG

1

8 Triple Pole Ways Panelboard (2 x 250A

+ 6 x 125A

)

JF80206B

JF80206BG

8 Triple Pole Ways Panelboard (4 x 250A

+ 4 x 125A

)

JF80404B

JF80404BG

12 Triple Pole Ways Panelboard (2 x 250A

+ 10 x 125A

)

JF80210B

JF80210BG

12 Triple Pole Ways Panelboard (4 x 250A

+ 8 x 125A

)

JF80408B

JF80408BG

18 Triple Pole Ways Panelboard (4 x 250A

+ 14 x 125A

)

JF80414B

JF80414BG

18 Triple Pole Ways Panelboard (6 x 250A

+ 12 x 125A

)

JF80612B

JF80612BG

Description

Max cable capacity Cat ref.

4 Pole 400A Load Break Switch 25kA

M10 Lug

JF844BSW

4 Pole 630A Load Break Switch 25kA

M12 Lug

JF864BSW

4 Pole 800A Load Break Switch

M12 Lug

*800LBS

800A Direct Connection Kit 4 Pole

M12 Lug

JF884BD

3 Pole 400A MCCB Incomer Kit 50kA

Electronic LSI MCCB,

I r adjustable 0.4 – 1.0 x I n

M12 Lug

JF843BM

4 Pole 400A MCCB Incomer Kit

Electronic LSI MCCB,

I r adjustable 0.4 – 1.0 x I n

M12 Lug

JF844BM

3 Pole 630A MCCB Incomer Kit 50kA

Electronic LSI MCCB,

I r adjustable 0.4 – 1.0 x I n

M12 Lug

JF863BM

4 Pole 630A MCCB Incomer Kit 50kA

Electronic LSI MCCB,

I r adjustable 0.4 – 1.0 x I n

M12 Lug

JF864BM

JF608B

Characteristics

-

-

Comprises of IP3XD enclosure, pan assembly, neutral bar and earth bar.

-

-

Conforms to BS EN 61439-2. I nA = 630/800A, I nc = 125A, I cc = 50kA.

-

-

Supplied without incoming kit, one of the incomer kits listed below must be used.

-

-

Form 3B type 2 using outgoing terminal shield (form 3A without terminal shield).

-

-

Removable gland plates are provided top and bottom for ease of installation.

-

-

Switch Disconnector: 630A/800A, MCCB: 400A/630A, Direct connection: 800A.

-

-

Incoming cable lugged via M12 hexagonal bolt.

-

-

For dimensions see page

1.57.

Cable Capacity Incomers & Outgoers

Incomers: 400A: 2 x 240mm², 630A: 2 x 240mm² / 2 x 300mm².

Outgoers: Single pole up to 125A - 70mm² flexible, 95mm² solid, Triple pole up to 250A - 150mm² flexible.

Outgoing MCCBs

-

-

Adjustable thermal options on triple pole.

Characteristics

-

-

These boards will accept a range of MCCB frame sizes: 125A frame: 16-125A single pole/triple pole, 250A frame: 80-250A

triple pole only

-

-

I nA = 630/800A, I nc = 250A, I cc = 50kA.

1

Max allowed incomer of 630A on this

panelboard.

* Select the required 630A/800A rated

panelboard (e.g.

JF80206BG

) and add

the suffix

800LBS

e.g.

JF80206BG800LBS

Characteristics

-

-

A 300mm cable spreader box (

JF805E

) is required for all incomer kits.

Commercial

Distribution