Data is subject to errors and technical modifications.
2.31
Modular Devices
& Enclosures
Timers
Electromechanical Time Switches
Electromechanical Time Switches
Digital Time Switches
Characteristics
-
-
For hourly, daily or weekly programming.
-
-
To control lighting, heating, ventilation, household appliances etc. to save energy and to improve comfort.
Technical Data
-
-
Programming by captive segments.
-
-
Manual override for 1 module products: Automatic, Permanent ON.
-
-
Manual override for 3 module products: Automatic, Permanent ON, Permanent OFF.
-
-
Minimum Switching Time: 15 min for daily dial, 2h for weekly dial.
-
-
Supply failure reserve where applicable 200 hours, after being connected for 120 hours.
-
-
For a selection chart see page
2.62,for technical data see page
2.61.Connection
-
-
1-4mm².
Characteristics
-
-
For the control of lighting, heating, household appliances, shop windows, signage etc. to improve comfort and to save
energy.
EG103
and
EG203
(Basic Version)
-
-
Automatic change of summer / winter time.
EG103E/V
and
EG203E
(Advanced Version)
-
-
Automatic change of summer / winter time.
-
-
Holiday mode: forcing ON or OFF between two dates, presence simulation with random switching.
-
-
Backlit screen.
-
-
Impulse programming capability (1s to 30 min).
Programming Key
-
-
To allow easy back up and re-installation of the program to allow permanent program overrides.
-
-
Programming per day or group of days.
-
-
56 ON / OFF programme steps.
-
-
Permanent ON/OFF overrides.
-
-
Temporary ON/OFF overrides bar graph indication showing the daily profile.
-
-
Ability to disable device button controls with
EG004
.
-
-
Programming can be completed without the need to be energised.
Connection
-
-
EG010
/
EG071
: 0.5 to 4mm².
-
-
EG103
and
EG203/E
: 1 to 6mm² Flexible, 1.5 to 10mm² Rigid.
Operating Voltage
-
-
230 a.c. 50/60 Hz (except
EG103V
- 12/24V AC/DC).
-
-
For a selection chart see page
2.62,for technical data see pages
2.61-
2.65.EH010
EG071
EH171
EG103
Description
Voltage Supply
Width
(1 Mod =17.5mm)
Cat ref.
1 Channel Time Switches without Supply Failure Reserve
Daily Dial, 1 Changeover Contact, 16A 250V a.c. AC1
230V a.c. 50Hz 1 Mod
EH010
Daily Dial, 1 NO Contact, 16A 250V a.c. AC1
230V a.c. 50Hz 3 Mod
EH110
1 Channel Time Switches with Supply Failure Reserve
Daily Dial, 1 Changeover Contact, 16A 250V a.c. AC1
230V a.c. 50/60Hz 1 Mod
EH011
Daily Dial, 1 NO Contact, 16A 250V a.c. AC1
230V a.c. 50/60Hz 3 Mod
EH111
Weekly Dial, 1 NO Contact, 16A 250V a.c. AC1
230V a.c. 50/60Hz 3 Mod
EH171
Description
Width
(1 Mod =17.5mm)
Cat ref.
1 Channel Digital Time Switch (not compatible with program key)
Daily Cycle, 5 Adjustable pre-recorded programs
6 Switchings per day (3 on and 3 off), Output: 1 changeover contact
16A - 250V a.c. AC 1, 3 year reserve
1 Mod
EG010
Weekly Cycle, Capacity 20 program steps
Output: 1 changeover contact
16A - 250V a.c. AC 1, 3 year reserve
1 Mod
EG071
1 Channel Digital Time Switch
Weekly Cycle (Basic Version), Output: 1 changeover contact
16A - 250V a.c. AC 1, Delivered with key
EG005
2 Mod
EG103
Weekly Cycle (Advanced Version), Output: 1 changeover contact
16A - 250V a.c. AC 1, Delivered with key
EG005
2 Mod
EG103E
2 Channel Digital Time Switch
Weekly Cycle (Basic Version), Output: 2 changeover contact
16A - 250V a.c. AC 1, Delivered with key
EG005
2 Mod
EG203
Weekly Cycle (Advanced Version), Output: 2 changeover contact
16A - 250V a.c. AC 1, Delivered with key
EG005
2 Mod
EG203E
EG203