Accessories and spare parts
2/76
Siemens LV 10.1 · 2011
* You can order this quantity or a multiple thereof.
✓
Additional price
1)
Only the right-hand accessory compartment and the N conductor (4-pole)
accessory compartment can be used for the installation of accessories,
see Technical Information at
www.siemens.com/lowvoltage/support.
2)
The assembly kit consists of the mounting plate, wiring and covers for cir-
cuit breakers and RCD module (for 75 mm standard mounting rail).
The RCD module (3VL9 112-5GA30/-5GA40) must be ordered separately.
3)
VL160X (3VL1) + RCD module cannot be combined with motorized operat-
ing mechanism, front operating mechanism, door-coupling rotary operat-
ing mechanism, locking device for toggle levers, screw terminal
connections (3VL17..-....6-....) and Bowden wire interlocking.
Circuit breakers
for system pro-
tection,
only for
TM, starters,
disconnectors
Rated
current
I
n
Residual
currents
I
adjust-
able
Delay time t
d
adjustable
Rated
operational
voltage U
e
DT Order No.
Price
per PU
PU
(UNIT,
SET, M)
PS*/
P. unit
PG Weight
per PU
approx.
A
A
s
V AC
kg
RCD modules
SENTRON VL160X
with RCD module
mounted laterally on
the circuit breaker
(on left side)
3-pole
VL160X (3VL1)
0.03
Instantaneous
Bottom
mounting
1)3)
160 0.10
0.30
0.50
1.00
3.00
0.06
0.10
0.25
0.50
1.00
127 ... 480 A
3VL9 112-5GA30
1 1 unit 113 1.340
Mounting kit for
left side,
without
RCD
1)2)3)
A
3VL9 112-5GB30
1 1 unit 113 1.525
VL160 (3VL2) 160
127 ... 480 A
3VL9 216-5GC30
1 1 unit 113 1.320
230 ... 690 A
3VL9 216-5GD30
1 1 unit 113 1.320
VL250 (3VL3) 250
127 ... 480 A
3VL9 325-5GE30
1 1 unit 113 1.400
230 ... 690 A
3VL9 325-5GF30
1 1 unit 113 1.400
VL400 (3VL4) 400
127 ... 480
--
230 ... 690
--
SENTRON VL160X
up to VL400 with
RCD module
mounted below the
circuit breaker
4-pole
VL160X (3VL1)
0.03
Instantaneous
Bottom
mounting
1)3)
160 0.10
0.30
0.50
1.00
3.00
0.06
0.10
0.25
0.50
1.00
127 ... 480 A
3VL9 112-5GA40
1 1 unit 113 1.590
Mounting kit for
left side,
without
RCD
1)2)3)
A
3VL9 112-5GB40
1 1 unit 113 1.824
VL160 (3VL2) 160
127 ... 480 A
3VL9 216-5GC40
1 1 unit 113 1.570
230 ... 690 A
3VL9 216-5GD40
1 1 unit 113 1.570
VL250 (3VL3) 250
127 ... 480 A
3VL9 325-5GE40
1 1 unit 113 1.650
230 ... 690 A
3VL9 325-5GF40
1 1 unit 113 1.650
VL400 (3VL4) 400
127 ... 480 A
3VL9 440-5GG40
1 1 unit 113 2.980
230 ... 690 A
3VL9 440-5GH40
1 1 unit 113 2.980
Circuit breakers
for system pro-
tection,
only for
TM, starters,
disconnectors
Rated
current
I
n
Residual
currents
I
adjust-
able
Delay time t
d
adjustable
Rated
operational
voltage U
e
3-pole
circuit breakers
4-pole
circuit breakers
Order No. with
"-Z"
3VL.
. .
. -
. D
.
.
. -
.
.
.
. -Z
and additional
order code
Addi-
tional
price
Order No. with
"-Z"
3VL.
. .
. -
. E
.
.
. -
.
.
.
. -Z
and additional
order code
Addi-
tional
price
A
A
s
V AC
@ @ @
Code for further
versions -
Z
@ @ @
Code for further
versions -
Z
Circuit breakers with RCD module
3 and 4-pole
VL160X (3VL1)
0.03
Instantaneous
(Bottom
mounting)
160 0.10
0.06
127 ... 480
A 0 1
1)3)
✓
A 0 1
1)3)
✓
0.30
0.10
0.50
0.25
VL160 (3VL2) 160 1.00
0.50
127 ... 480
A 0 1
✓
A 0 1
✓
3.00
1.00
230 ... 690
A 0 2
✓
A 0 2
✓
VL250 (3VL3) 250
127 ... 480
A 0 1
✓
A 0 1
✓
230 ... 690
A 0 2
✓
A 0 2
✓
VL400 (3VL4) 400
127 ... 480
--
A 0 1
✓
230 ... 690
--
A 0 2
✓
NSE0_00582
NSE0_00583