Background Image
Table of Contents Table of Contents
Previous Page  76 / 98 Next Page
Information
Show Menu
Previous Page 76 / 98 Next Page
Page Background

Accessories and spare parts

2/76

Siemens LV 10.1 · 2011

* You can order this quantity or a multiple thereof.

Additional price

1)

Only the right-hand accessory compartment and the N conductor (4-pole)

accessory compartment can be used for the installation of accessories,

see Technical Information at

www.siemens.com/lowvoltage/support.

2)

The assembly kit consists of the mounting plate, wiring and covers for cir-

cuit breakers and RCD module (for 75 mm standard mounting rail).

The RCD module (3VL9 112-5GA30/-5GA40) must be ordered separately.

3)

VL160X (3VL1) + RCD module cannot be combined with motorized operat-

ing mechanism, front operating mechanism, door-coupling rotary operat-

ing mechanism, locking device for toggle levers, screw terminal

connections (3VL17..-....6-....) and Bowden wire interlocking.

Circuit breakers

for system pro-

tection,

only for

TM, starters,

disconnectors

Rated

current

I

n

Residual

currents

I

adjust-

able

Delay time t

d

adjustable

Rated

operational

voltage U

e

DT Order No.

Price

per PU

PU

(UNIT,

SET, M)

PS*/

P. unit

PG Weight

per PU

approx.

A

A

s

V AC

kg

RCD modules

SENTRON VL160X

with RCD module

mounted laterally on

the circuit breaker

(on left side)

3-pole

VL160X (3VL1)

0.03

Instantaneous

Bottom

mounting

1)3)

160 0.10

0.30

0.50

1.00

3.00

0.06

0.10

0.25

0.50

1.00

127 ... 480 A

3VL9 112-5GA30

1 1 unit 113 1.340

Mounting kit for

left side,

without

RCD

1)2)3)

A

3VL9 112-5GB30

1 1 unit 113 1.525

VL160 (3VL2) 160

127 ... 480 A

3VL9 216-5GC30

1 1 unit 113 1.320

230 ... 690 A

3VL9 216-5GD30

1 1 unit 113 1.320

VL250 (3VL3) 250

127 ... 480 A

3VL9 325-5GE30

1 1 unit 113 1.400

230 ... 690 A

3VL9 325-5GF30

1 1 unit 113 1.400

VL400 (3VL4) 400

127 ... 480

--

230 ... 690

--

SENTRON VL160X

up to VL400 with

RCD module

mounted below the

circuit breaker

4-pole

VL160X (3VL1)

0.03

Instantaneous

Bottom

mounting

1)3)

160 0.10

0.30

0.50

1.00

3.00

0.06

0.10

0.25

0.50

1.00

127 ... 480 A

3VL9 112-5GA40

1 1 unit 113 1.590

Mounting kit for

left side,

without

RCD

1)2)3)

A

3VL9 112-5GB40

1 1 unit 113 1.824

VL160 (3VL2) 160

127 ... 480 A

3VL9 216-5GC40

1 1 unit 113 1.570

230 ... 690 A

3VL9 216-5GD40

1 1 unit 113 1.570

VL250 (3VL3) 250

127 ... 480 A

3VL9 325-5GE40

1 1 unit 113 1.650

230 ... 690 A

3VL9 325-5GF40

1 1 unit 113 1.650

VL400 (3VL4) 400

127 ... 480 A

3VL9 440-5GG40

1 1 unit 113 2.980

230 ... 690 A

3VL9 440-5GH40

1 1 unit 113 2.980

Circuit breakers

for system pro-

tection,

only for

TM, starters,

disconnectors

Rated

current

I

n

Residual

currents

I

adjust-

able

Delay time t

d

adjustable

Rated

operational

voltage U

e

3-pole

circuit breakers

4-pole

circuit breakers

Order No. with

"-Z"

3VL.

. .

. -

. D

.

.

. -

.

.

.

. -Z

and additional

order code

Addi-

tional

price

Order No. with

"-Z"

3VL.

. .

. -

. E

.

.

. -

.

.

.

. -Z

and additional

order code

Addi-

tional

price

A

A

s

V AC

@ @ @

Code for further

versions -

Z

@ @ @

Code for further

versions -

Z

Circuit breakers with RCD module

3 and 4-pole

VL160X (3VL1)

0.03

Instantaneous

(Bottom

mounting)

160 0.10

0.06

127 ... 480

A 0 1

1)3)

A 0 1

1)3)

0.30

0.10

0.50

0.25

VL160 (3VL2) 160 1.00

0.50

127 ... 480

A 0 1

A 0 1

3.00

1.00

230 ... 690

A 0 2

A 0 2

VL250 (3VL3) 250

127 ... 480

A 0 1

A 0 1

230 ... 690

A 0 2

A 0 2

VL400 (3VL4) 400

127 ... 480

--

A 0 1

230 ... 690

--

A 0 2

NSE0_00582

NSE0_00583