3-pole
2/18
Siemens LV 10.1 · 2011
* You can order this quantity or a multiple thereof.
1)
Front busbar connection pieces are included in the scope of supply
and are to be fitted by the customer.
Communication:
• For accessories, see page 2/98.
• For more information see also chapters "Measuring Devices
and E-Counters" and "Software".
Type
Rated
current
I
n
Current
setting of the
inverse-time
delayed
overcurrent
releases "
L
"
I
R
Operating
current of
the instan-
taneous
short-
circuit
releases
"
I
"
I
i
S function
short-
circuit
protection
(short-time
delayed)
S
Ground-fault
protection "
G
"
I
g
DT
I
cu
up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
For price
see page
2/32
PU
(UNIT,
SET, M)
PS*/
P. unit
PG Weight
per PU
approx.
Order No. supple-
ment required,
see page 2/57
A
A
A
A
A
kg
3-pole, fixed-mounted, for system protection - generator protection,
63 A to 1600 A, electronic releases LSIG
ETU22, LSIG function for 3-wire three-phase systems and time-based discrimination
With adjustable overcurrent releases, non-adjustable short-circuit releases,
ground fault delay t
g
= 0.1 ... 0.3 s, short-circuit delay t
sd
= 0 ... 0.5 s, ground-fault protection (G) can be switched off
VL160/3VL2 63
25 ... 63 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL27 06-1
@@
3
@
-....
1 1 unit 113 2.400
100
40 ... 100 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL27 10-1
@@
3
@
-....
1 1 unit 113 2.400
160
64 ... 160 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL27 16-1
@@
3
@
-....
1 1 unit 113 2.400
VL250/3VL3 200
80 ... 200 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL37 20-1
@@
3
@
-....
1 1 unit 113 2.500
250 100 ... 250 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL37 25-1
@@
3
@
-....
1 1 unit 113 2.500
VL400/3VL4 315 128 ... 315 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL47 31-1
@@
36-....
1 1 unit 113 5.900
400 160 ... 400 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL47 40-1
@@
36-....
1 1 unit 113 5.900
VL630/3VL5 630 252 ... 630 10 ×
I
n
1.5 ... 9x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL57 63-1
@@
36-....
1 1 unit 113 9.300
VL800/3VL6 800 320 ... 800 8 ×
I
n
1.5 ... 7x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL67 80-1
@@
36-....
1 1 unit 113 16.000
VL1250/3VL7 1000 400 ... 1000 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL77 10-1
@@
36-....
1 1 unit 113 25.000
1250 500 ... 1250 11 ×
I
n
1.5 ... 10x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL77 12-1
@@
36-....
1 1 unit 113 25.000
VL1600/3VL8
1)
1600 640 ... 1600 9 ×
I
n
1.5 ... 8x
I
R
0.6 ... 1 ×
I
n
, OFF B
3VL87 16-1
@@
30-....
1 1 unit 113 31.300
N
L
S
I
G
NSE0_00694
1.0
Alarm
Active
>1.05
X3
x
I
n
R
I
6
5
7
sd
t
10
8
4
3
2
x
I
R
sd
I
NSE0_02121
(S)
t
I
I
ON
2
t
2
OFF
0
I
g
t
g
OFF
OFF
I
.5
.8
.7 .63
.9
.6
.45
.4
.95
1.5
2.5
.4
.5
.2
.3
.4
.3
.2
.1
.1
.6/.1
1/.1
.6/.1
1/.1
.6/.3
1/.3
.6/.3
1/.3
>
Connection type can be selected by assignment of the 12th position of the Order No.
• Connection with box terminal
3
• Connection with screw terminal
6
>
• Without communication preparation
SG
• With communication preparation
MG