Background Image
Table of Contents Table of Contents
Previous Page  120 / 164 Next Page
Information
Show Menu
Previous Page 120 / 164 Next Page
Page Background

120

WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION

PG00400018U – March 2012

MEMERA consumer units

Control and switching devices

11.6

See pages 151–155 for Contactors technical data and overall dimensions.

Contactors, 20 A – ac/dc coil

When several contactors are mounted it is advisable to fit a blanking module, List number MBP, every two contactors.

Description

Rating

Coil

Coil

Width

Contacts

Eaton list

(A)

voltage (Vac) voltage (Vdc) (mm)

number

Contactor

20

230

220

18

1 NO + 1 NC

CR2011230

Contactor

20

230

220

18

2 NC

CR2002230

Contactor

20

230

220

18

2 NO

CR2020230

CR2020024

Contactors, 25 A – ac coil

When several contactors are mounted it is advisable to fit a blanking module, List number MBP, every two contactors.

Description

Rating

Coil

Coil

Width

Contacts

Eaton list

(A)

voltage (Vac) voltage (Vdc) (mm)

number

Contactor

25

230

36

2 NO + 2 NC

CR2522230A

Contactor

25

230

36

3 NO

CR2530230A

Contactor

25

230

36

4 NC

CR2504230A

Contactor

25

230

36

4 NO

CR2540230A

CR2540230A

Contactors, 25 A – ac/dc coil

When several contactors are mounted it is advisable to fit a blanking module, List number MBP, every two contactors.

Description

Rating

Coil

Coil

Width

Contacts

Eaton list

(A)

voltage (Vac) voltage (Vdc) (mm)

number

Contactor

25

230

220

36

2 NO + 2 NC

CR2522230

Contactor

25

230

220

36

3 NO

CR2530230

Contactor

25

230

220

36

4 NC

CR2504230

Contactor

25

230

220

36

4 NO

CR2540230

CR2504024

Contactors, 40 A – ac/dc coil

When several contactors are mounted it is advisable to fit a blanking module, List number MBP, every two contactors.

Description

Rating

Coil

Coil

Width

Contacts

Eaton list

(A)

voltage (Vac) voltage (Vdc) (mm)

number

Contactor

40

230

220

54

2 NC

CR4002230

Contactor

40

230

220

54

2 NO

CR4020230

Contactor

40

230

220

54

3 NO

CR4030230

Contactor

40

230

220

54

4 NO

CR4040230

CR4030024

Contactors, 20 A – ac coil

When several contactors are mounted it is advisable to fit a blanking module, List number MBP, every two contactors.

Description

Rating

Coil

Coil

Width

Contacts

Eaton list

(A)

voltage (Vac) voltage (Vdc) (mm)

number

Contactor

20

230

18

1 NO + 1 NC

CR2011230A

Contactor

20

230

18

2 NC

CR2002230A

Contactor

20

230

18

2 NO

CR2020230A

CR2011230A