SYSTEM POWERSTAR

FORM 2 I NCOM I NG UN I T S

153

KI2L1

KI2L2

KI2J1

KEC2

KEE2

INDIVIDUAL ENCLOSURES AND CABLEWAYS

l

Enclosures are 768mm wide (4 mod). Cableways are 288mm wide

(1

1

/

2

mod). Both units are 265mm deep and have slotted sides to allow

horizontal access to any adjacent unit. Both are supplied with screw

fixed front cover plates.

INCOMING UNITS, FORM 2 MCCB PANEL BOARDS

l

These units use the same modular enclosures as the Form 2 Panel

Boards. Incoming assemblies include appropriate Form 2 shielding,

preformed copper interconnections, front plate/door, but NOT the

device itself.

MCCB Neutral Links supplied with Incoming Housing, whilst Fuse Switch

Neutral Links are supplied with the Switch itself.

Suitable for fixture below or above the Form 2

Panel Boards.

Mod

Height

Height

mm

Assembly to accommodate

1- ‘

N’ Frame, TP MCCB, Max rating 800A.

Front Flat Terminal MCCB only

5 960

KI2N1

See page 164 for MCCB details

Assembly to accommodate

1- ‘

L’ Frame, TP/4P MCCB, Max rating 630A. 4 768

KI2L1

See page 163 for MCCB details

Assembly to accommodate

2- ‘

L’ Frame, TP/4P MCCB, Max rating 630A 5 960

KI2L2

Includes horizontal Busbar and all connections.

See page 163 for MCCB details

Assembly to accommodate

1- ‘

J’ Frame, TP/4P MCCB, Max rating 200A. 3 576

KI2J1

See page 161 for MCCB details

Assembly to accommodate

1- ‘

F’ Frame, TP MCCB, Max rating 250A.

3 576

KI2F1

See page 162 for MCCB details

Assembly to accommodate

1- 315/400

Amp, TP&N/4P Fuse Switch 4 768

KI2S4

See page 141 for Fuse Switch details

Assembly to accommodate

1- 63, 100, 200

Amp, TP&N/4P Fuse Switch 3 576

KI2S2

See page 141 for Fuse Switch details

All Incoming Units supplied with 1-Gland/End Plate, 2-Side Plates and

1-

Cross Strap.

To accommodate 4 Pole MCCBs the prefitted Neutral Link must be removed.

Fuse Switches supplied with Neutral Link, Handle & Terminal Shroud.

See page 226 for cabling information.

Modular

Height

Cableway

Enclosure

Side

Height

mm 288mm W 768mm W Plate

1

192

KEC1

KEE1

KXESP1

2

384

KEC2

KEE2

KXESP2

3

576

KEC3

KEE3

KXESP3

4

768

KEC4

KEE4

KXESP4

5

960

KEC5

KEE5

KXESP5

6

1152

KEC6

KEE6

KXESP6

Enclosures supplied with 1-Gland/End Plate, 2 Side Plates and 1-Cross Strap.