Background Image
Table of Contents Table of Contents
Previous Page  14 / 133 Next Page
Information
Show Menu
Previous Page 14 / 133 Next Page
Page Background

POL ESTAR

MCB S & RCBOS

135

60

B/32

60

B/40

63

C/16

63

C/32

62

B/10

602

C/323

MINIATURE CIRCUIT BREAKERS (MCB)

l

Current

Single Pole

Rating (A)

Type B

Type C

Type D

LIST No

LIST No

LIST No

6

60

B/06

60

C/06

60

D/06

10

60

B/10

60

C/10

60

D/10

16

60

B/16

60

C/16

60

D/16

20

60

B/20

60

C/20

60

D/20

32

60

B/32

60

C/32

60

D/32

40

60

B/40

60

C/40

60

D/40

50

60

B/50

60

C/50

60

D/50

63

60

B/63

60

C/63

60

D/63

Current

Double Pole

Rating (A)

Type B

Type C

Type D

LIST No

LIST No

LIST No

6

62

B/06

62

C/06

62

D/06

10

62

B/10

62

C/10

62

D/10

16

62

B/16

62

C/16

62

D/16

20

62

B/20

62

C/20

62

D/20

32

62

B/32

62

C/32

62

D/32

40

62

B/40

62

C/40

62

D/40

50

62

B/50

62

C/50

62

D/50

63

62

B/63

62

C/63

62

D/63

Current

Triple Pole

Rating (A)

Type B

Type C

Type D

LIST No

LIST No

LIST No

6

63

B/06

63

C/06

63

D/06

10

63

B/10

63

C/10

63

D/10

16

63

B/16

63

C/16

63

D/16

20

63

B/20

63

C/20

63

D/20

32

63

B/32

63

C/32

63

D/32

40

63

B/40

63

C/40

63

D/40

50

63

B/50

63

C/50

63

D/50

63

63

B/63

63

C/63

63

D/63

BS EN 60 898.

Type B (3–5In), C (5–10In), D (10–20In) classification.

Short circuit duty rating: Type B/C 16000A 240V/415V 50Hz.

Short circuit duty rating:

Type D 10000A 240V/415V 50Hz.

Terminal capacity up to 25mm

2

cable.

25

mm modular width.

RESIDUAL CURRENT CIRCUIT BREAKERS

WITH OVERCURRENT PROTECTION (RCBO)

l

Double Pole

Type AC

MCB Type C

normal ac sensitivity

Current rating (A)

LIST No

6

602

C/063

10

602

C/103

16

602

C/163

20

602

C/203

32

602

C/323

40

602

C/403

Standard compliance BS EN 61009; IEC 1009.

Short circuit duty rating 10000A 240V 50Hz.

Electromechanical RCD, 30mA. Double pole operation.

Terminal capacity up to 25mm

2

cable.

INDIVIDUAL SWITCH DISCONNECTORS

l

LIST No

125

A TP Switch disconnector

125

SW3

125

A TP Switch disconnector heavy duty

125/3

MS

200

A TP Switch disconnector

200/3

MS

BS EN60947-3.

Switch disconnectors suitable for individual and panel mounting applications.

Complete with terminal shrouds.

Maximum cable capacities 125A – 50mm

2

.

Maximum cable capacities

200

A – 120mm

2

.

200

A fitted with Allen headed terminals enabling incoming cable to be more

effectively secured (Allen key supplied).