7/28 jokab safety

ABB Low Voltage Industrial Products 0312

7

A laser scanner that has the ability to scan four

individual areas

The Laser Scanner ’Look’ has the ability to scan four individual

areas. Each area can be programmed individually for the specific

application, making it ideal for auto-carriers that need to operate

along different paths. The safety level is according to Type 3, EN

61496-3. It is approved for use as personnel protection in robot

working areas, conveyor equipment etc. The small design makes

it easy to install. Look is not affected by ambient light levels (sun

etc) or welding arcs/sparks. The protection fields are quick and

easy to create on a PC in a Windows environment. It has four

individual programmable protection areas. Each area consists of

one personnel protection field with maximum 4 m radius, and one

warning field of maximum 15 m radius. Changing between the

areas is easily achieved using additional sensors.

Safety light grids, curtains and scanners

Look

- laser scanner

TÜV Süd

Technical data - general

Description

Safety level

EN/IEC 61496

EN 954-1

EN ISO 13849-1

Type 3

Category 3

PL d

PFH

d

1,50E-07

General data

Scanning rate:

Scanning angle:

Operating voltage:

Transmitter:

Current consumption:

Angle resolution:

Weight:

Housing:

25 Scans/sec

190°

24 VDC +20%/ -30%

Laserdiode; Protection class 1

approx. 300 mA

0,36°

2 kg

H=155 mm, W=140 mm, D=135 mm

Personnel protection field

Scanning distance:

Area:

Output:

Resolution:

Response time:

Reflectance factor:

Radius 0.2 - 4 m

4 areas, switchable by 24 VDC input

2 x OSSD; 250 mA; failsafe

transistor PNP outputs 24 VDC

70 mm at 4 m

80 ms

min 1,8 %

Warning field

Scanning distance:

Area:

Output:

Resolution:

Response time:

Reflectance factor:

Radius 0 - 15 m

4 areas, switchable by 24 VDC input

PNP-transistor, 24 VDC/100 mA

150 mm at 15 m, ± 20%

80 ms

min 20%

Contour measurement

Measurement range:

Output:

Response time:

Reflectance factor:

Reset:

Suitable interface safety relay:

Radius 0- 50 m

RS 232/422

80 ms

min 20%

manual or automatic

RT6, RT7, RT9, JSBRT11 or Pluto

Conformity:

Machine directive

2006/42/EG

EN ISO 12100-1/2, EN 954-1,

EN ISO 13849-1, -2, EN 61496-1

Selection

Product Hierarchy 4700004

Part No

Order Code

Price

Look JS4-4

50034195

251.31

Photoelectric guarding of several risk areas

Type 3, IEC61496-3

Easy to install

Protected from welding sparks/arcs

Easy to program

4 individual programmabprotection areas

simultaneously with Pluto