3VT1 Molded Case Circuit Breakers up to 160 A
Circuit breakers · Switch disconnectors
2/3
Siemens LV 36 · 2008
2
■
Overview
Circuit breakers
Circuit breakers, 3-pole version
The 3-pole version of the circuit breakers consits pf:
• 2 connecting sets for connecting Cu/Al cables
1)
with cross-
sections of 2.5 ... 95 mm
2
(these terminals are fitted to the circuit breaker)
• 3VT9 100-8CE30 phase barriers
• A set of two mounting bolts (M3 x 30)
• A conductor holder
Characteristic M (motor): motor protection
Circuit breakers, 4-pole version
The 4-pole version of the circuit breakers consists of:
• 2 connecting sets for connecting Cu/AI cables
1)
with cross-
sections of 2.5 ... 95 mm
2
(these terminals are fitted to the circuit breaker)
• 3VT9 100-8CE30 and 3VT9 100-8CE00 phase barriers
• 2 sets of two mounting bolts (M3 x 30)
• A conductor holder (installed in the circuit breaker)
Releases:
Characteristic L (line)
• Protecting lines with low starting currents
• Without
I
r
regulation
Characteristic D (distribution)
• Protecting lines and transformers
Characteristic N (only short-circuit release)
• Without
I
r
regulation
Switch disconnectors
Switch disconnectors, 3-pole version
The 3-pole version of the switch disconnectors consits of:
• 2 connecting sets for connecting Cu/Al cables
1)
with cross-
sections of 2.5 ... 95 mm
2
(these terminals are fitted to the switch disconnector)
• 3VT9 100-8CE30 phase barriers
• A set of two mounting bolts (M3 x 30)
• A conductor holder
Switch disconnectors, 4-pole version
The 4-pole version of the switch disconnectors consits of:
• 2 connecting sets for connecting Cu/Al cables
1)
with cross-
sections of 2.5 ... 95 mm
2
(these terminals are fitted to the switch disconnector)
• 3VT9 100-8CE30 and 3VT9 100-8CE00 phase barriers
• 2 sets of two mounting bolts (M3 x 30)
• Conductor holder (installed in the switch disconnector)
Connection
When connecting the main circuit, the dimensions of the deion-
ization space of the circuit breaker must be observed, depend-
ing on the type of connection
(see pages 2/35 and 2/36)
.
1)
For other connection methods, use connecting parts
(see page 2/9).
■
Selection and ordering data
Rated current
I
n
Current setting of the inverse-time
delayed overload release „L“
I
r
DT Order No.
PS*
Weight
per PU
approx.
A
A
kg
Circuit breakers for system protection characteristic L
TM, LI function, 3P
• with fixed thermal overload release,
fixed short-circuit release
40
160
B
3VT1 704-2DA36-0AA0
1 unit 1.043
50
200
B
3VT1 705-2DA36-0AA0
1 unit 1.043
63
252
B
3VT1 706-2DA36-0AA0
1 unit 1.062
80
320
B
3VT1 708-2DA36-0AA0
1 unit 1.062
100
400
B
3VT1 710-2DA36-0AA0
1 unit 1.047
125
500
B
3VT1 712-2DA36-0AA0
1 unit 1.047
160
640
B
3VT1 716-2DA36-0AA0
1 unit 1.074
TM, LI function, 3P+N, for unprotected conductors
• with fixed thermal overload release,
fixed short-circuit release
40
160
B
3VT1 704-2EA46-0AA0
1 unit 1.336
50
200
B
3VT1 705-2EA46-0AA0
1 unit 1.336
63
252
B
3VT1 706-2EA46-0AA0
1 unit 1.336
80
320
B
3VT1 708-2EA46-0AA0
1 unit 1.336
100
400
B
3VT1 710-2EA46-0AA0
1 unit 1.336
125
500
B
3VT1 712-2EA46-0AA0
1 unit 1.336
160
640
B
3VT1 716-2EA46-0AA0
1 unit 1.336
TM, LI function, 4P
• with fixed thermal overload release,
fixed short-circuit release
40
160
B
3VT1 704-2EH46-0AA0
1 unit 1.336
50
200
B
3VT1 705-2EH46-0AA0
1 unit 1.336
63
252
B
3VT1 706-2EH46-0AA0
1 unit 1.336
80
320
B
3VT1 708-2EH46-0AA0
1 unit 1.336
100
400
B
3VT1 710-2EH46-0AA0
1 unit 1.336
125
500
B
3VT1 712-2EH46-0AA0
1 unit 1.336
160
640
B
3VT1 716-2EH46-0AA0
1 unit 1.336
* You can order this quantity or a multiple thereof.