TL 32 A impulse relays
Remote control
Technical
Section 9
Dimensions
Section 10
5
Operation
Closing of the impulse relay pole(s) is triggered by an impulse on the coil.
Equipped in the factory with two stable mechanical positions, the pole(s) will be
opened by the next impulse. Each impulse received by the coil reverses the position
of the pole(s).
b
Manual controls on front face:
v
v
Direct and priority manual control by O-l toggle
v
v
Disconnection of remote control by selector switch (except for single-piece TL)
b
Indication: mechanical on front face by toggle position
Technical data
Rating
32 A, cos
j
= 0.6
Voltage rating
TL: 1P 250 V, 50/60 Hz
TL: 2P, 3P, 4P (TL+ETL): 415 V, 50/60 Hz
Inrush power
1P: 19 VA, 2P: 38 VA, 3P: 57 VA, 4P: 76 VA
Control voltage (Uc)
Tolerance at 50 Hz: Uc +6 % -15 %
Tolerance at 60 Hz: Uc ±6 %
Tolerance in DC: +6 % -10 %
Impulse duration
50 ms (recommended value for automation
system: 200 ms)
Maximum switching frequency 5 switching operations/minute
Noise level on
energisation
y
60 dBA (at 1 m)
Electrical durability
50,000 cycles (AC21), 20,000 cycles (AC22)
Operating
temperature
-20 °C to +50 °C
Tropicalisation
Treatment 2 (relative humidity 95 % at +55 °C)
Connection
Screw “±”, Posidriv
Connection
terminals
Power circuit: tunnel terminals for cables up to
10 mm
2
Control circuit: tunnel terminals for 0.5 to 6 mm
2
cables
Type
Width in
mod.
Coil voltage Uc
Part number
of 9 mm (V AC)
(V DC)
TL 32 A impulse relays
1P
2
230...240
110
15515
2P
2 + 2
230...240
110
15515 + 15505
3P
2 + 4
230...240
110
15515 + 2 x
15505
4P
2 + 6
230...240
110
15515 + 3 x
15505
32 A ETL extensions
2
230...240
110
15505
Accessories
Set of 10 clips
15415