5/7
TR transformers
Local control and
indication
Technical
Section 9
Dimensions
Section 10
Technical data
Primary voltage:
230 V CA ±10 %.
Secondary voltage on load: 8-12-24 V CA ±15 % for bell transformers
12-24 V CA ±5 % for safety transformers
Frequency:
50/60 Hz
Compliance with standards: NF EN 60742, EN and IEC 61558-2-6
Approval NF USE
Connection:
Tunnel terminals for cables up to 4 mm
2
Transformer
Rated
Off load voltage (V)
Part number
secondary voltage (V)
15214
8
12
15213
8
12
12
16
15216
8
13
12
18
15212
8
13
12
18
15215
12
16
24
32
15218
12
14
24
28
15219
12
14
24
28
15220
12
14
24
28
15222
12
14
24
28
Note
: Transformers have an off load operating voltage that is higher than the rated voltage. For loads that
are sensitive to overloads (electro-magnetic circuits), the transformer must be made to operate at ln. After
operation of the protection device upon an overload, cut-off the power supply and let the transformer cool
down before restart.
Function
Bell transformers and safety transformers allow for a very low voltage
(ELV 8 V, 12 V or 24 V) to be obtained from a low voltage network (LV 230 V).
Description
All Multi 9 transformers are:
n
Safe: primary and secondary circuits are perfectly insulated by each other.
n
Resistant to short-circuit currents thanks to the built-in device.
n
Class II with terminal shield (optional)
Power
Secondary
Width in
Part
(VA)
voltage
18mm
number
(V AC)
SP ways
Bell transformer
4
8
2
15214
4
8-12
2
15213
8
8-12
2
15216
16
8-12
2
15212
25
12-24
3
15215
Safety transformer
16
12-24
5
15218
25
12-24
5
15219
40
12-24
5
15220
63
12-24
5
15222
Terminal shield
2
15228
3
15229
5
15230
1
7
230 V
4
8
8 V
15214
24 V
1
7
230 V
12 V 6
8
4
15215
12 V
1
7
230 V
8 V 6
8
4
15212-15213-15216
24 V
1
7
230 V
12 V 10
12
8
24 V
7
230 V
6
12 10
8
1
12 V
7
230 V
6
12 10
8
1
15218-15219
15220-15222
15220-15222