7/106
63.5
50.5
IP 65 connector-free cable entries:
Two solutions to suit your application
Circular
Compact, flexible system for inserting cables in electrical
enclosures or connection boxes, for example:
Specifications
● IP 65 tightness.
● Fire resistance: V0.
● Cut-outs 50 and 63 mm.
● Installation by nut, up to Spacial wall-mounting steel enclosure size
700 500 250 mm.
● 2 installation methods are possible for sizes larger than 700 500 250 mm:
clipping or screwing (installation by screwing recommended).
Composition: 10 units.
Reference by unit. Order by multiples of 10 (10, 20, 30...).
Rectangular
Compact, flexible system for inserting cables in electrical enclosures
or connection boxes, for example:
● External dimensions: 146 14 58 mm.
● Drill-hole diameter: 112 36 mm.
Specifications
● IP 65 tightness.
● Fire resistance: V0.
● Identical cut-outs to the 24-point connectors.
● Installation by screwing, up to Spacial wall-mounting steel enclosure size
700 500 250 mm.
● 2 installation methods are possible for sizes larger than 700 500 250 mm:
clipping or screwing (installation by screwing recommended).
5.5
112
36
2
9
32
Cable entries
07_105_108_SPA001.indd 106