Floor
>
Advantage:
Fixing convenience and speed.
2
Fixing from the outside of the enclosure with a M12 screw, screwing directly onto
the vertical upright.
>
Advantage:
Maximum rigidity of the enclosure-plinth assembly.
Possibility of fixing the plinth to the floor
1
Fixing from the inside of the enclosure.
The machining angle varies according to the plinth model:
Plinth height 100 mm = 18º.
Plinth height 200 mm = 9º
Possibility of fixing the enclosure to the plinth
1
Fixing from the inside of the enclosure by means of an M12 screw, screwing
directly into the corner of the plinth.
2
Fixing from the outside of the enclosure, optimum point for the rigidity of the
assembly.
The machining angle varies according to the plinth model:
Plinth height 100 mm = 22º.
Plinth height 200 mm = 11º.
3
It is also possible to use floor-fixing supports, reference
NSYSGF
, to fix the
corner or the panel and the corner to the floor.
The corners of the ends can be rotated in the event of needing to remove the side
panels of the plinth and/or to obtain access to the fixing outside the floor, when the
set is installed against the wall.
03_038_SFM013.indd 38
28/1