19
Qwikline ll - split load consumer unit technical data
Insulated units
Reference number
Cir A
RCD ways
Height
Width
Depth
SQOS2R4
2
4
240
296
127
SQOS3R3
3
3
240
296
127
SQOS4R2
4
2
240
296
127
SQOS4R6
4
6
240
368
127
SQOS5R5
5
5
240
368
127
SQOS6R4
6
4
240
368
127
SQOS7R3
7
3
240
368
127
SQOS7R7
7
7
240
440
127
Metal units
Reference number
Cir A
RCD ways
Height
Width
Depth
SQOMS4R6
4
6
247
366
111
SQOMS5R5
5
5
247
366
111
SQOMS6R4
6
4
247
366
111
SQOMS7R7
7
7
247
438
111
Note:
Split load units are supplied without incoming devices.
These should be selected separately from the Qwikline ll devices section.
e.g. SQOS2R4 + SQO1100M + SQOE063030 = 2+4 Split load insulated consumer unit supplied with site installable switch
disconnector and 63A 30mA RCCB.
Any RCCB may be selected as the main incomer or split portion device.
Technical data
Metal
Insulated
Max. busbar current rating (A)
100
100
Max. operating voltage (V)
240
240
Operating frequency (Hz)
50
50
Max. incoming cable capacity mm
2
(phase and neutral)
50
50
Max. outgoing cable capacity mm
2
25
25
Certification
BS EN 61439-3
BS EN 61439-3
IP rating BS EN 60529 (internal)
2XB
2XB
Incoming
Switch disconnector – 100A
Terminal block
– 100A
RCCB’s
– 63 or 100A/30mA,
100 or 300mA
Control devices
May be installed at any outgoing
point on the RCD protected or
unprotected side
Outgoing
MCB’s – B or C curve, 3 - 50A
RCBO’s – B curve 45A, 6kA
Dimensions (mm)
Dimensions (mm)
No. of ways
No. of ways
Split
RCCB – 63 or 100A/30mA,
100 or 300mA